This website is being migrated. In case you don't find the information you are looking for, the old website can be found here. Thank you for reporting any anomalies to communication@ill.eu.

Vertical Field Magnets

Most cryomagnets are available from a pool on request. Sufficient advance notice to sane(at)ill.fr is required for their reservation and preparation. A small number of cryomagnets are assigned to specific instruments. The scientific and technical staff of the instruments concerned are in charge of their maintenance. However, major repairs and modifications are carried out in the workshop of the Services for Advanced Neutron Environment team.

All requests for liquid helium should be be made at least 48 hours in advance. Please arrange with your Local Contact to order your helium. If you are not familiar with transferring liquid helium between dewar and cryostat, please do not hesitate to call for assistance from your Local Contact or directly from the Services for Advanced Neutron Environment team.

Code Magneticfield (T) Gap(mm) Sample dim.Ø x height (mm) Temperaturerange Type Diameter(mm) Year

90ILHV42

2.5
asymmetric

30

Ø42x130*
Ø30 with dilution    

40mK - 300K

85° pillar
-5° to +5° vertical access

Ø286 in
scat. plane

1995

176ASHV49
(D2B)

6

40

Ø49

1.5 - 300

-3 to +3° vertical access

-

2006

156OXHV49
(CNRS)

6
asymmetric

40

Ø49x130*
Ø35 with dilution

40mK - 300K

-5° to +20° vertical access,
very low temperature
insert available

Ø388 in
scat. plane

1994

206OXHV26

7
asymmetric

30

Ø20 x 20

1.5 - 300

-5° to +5° vertical access,
±20° horizontal access,
sapphire windows,
He recondensation

390 in
scat. plane

2011

139OXHV40
(D3)

10
asymmetric

10

Ø10x10
or Ø38x20
Ø32 with dilution

40mK - 650K

-25° to +5° vertical access,
4 pillars of 43° at 90°

Ø512 in
scat. plane

1999

203OXHV39

10
asymmetric

40

Ø39x318*

40mK - 300K

-5° to +5° vertical access,
±130° horizontal access,
He recondensation

Ø598 in
scat. plane

2010

256CRHV41
(ToF)

10

40

Ø39x30

40mK - 300K

-15° to +15° vertical access,
2x90° windows

ů540 in
scat. plane

2017

283HTSHV39

12
asymmetric

30

Ø39x30

40mK - 300K

-11° to +2° vertical access,
very low temperature
insert available

Ø560 in
scat. plane

2025

158OXHV26

15

20

Ø25x285*
140 from M8
Ø18x64 with dilution

35mK - 300K

-2° to +2° vertical access

Ø598 in
scat. plane

2004

(*) Total available height in the calorimeter. The height of the neutron beam is necessarily less than the gap of the split-pair coil.