Error Codes
These error codes are related with the CORBA requests and returned by all interfaces. They are defined as follows:
| Codes | Description |
|---|---|
0 |
Operation was successful |
1 |
Instrument variable requested by MAD/NOMAD is non-existent. |
2 |
Instrument variable requested by MAD/NOMAD of bad data type. |
3 |
Instrument variable requested by MAD/NOMAD cannot be copied from handle. |
4 |
Instrument name sent by MAD/NOMAD doesn't match Igor's instrument name. |
5 |
The "NOMAD:Cryogenics" data folder does not exist. |
6 |
Cannot get the LN2 level (Igor variable does not exist). |
7 |
Cannot get the LN2 level (Igor variable of bad data type). |
8 |
Cannot get the LN2 level (Igor data/time variable does not exist). |
9 |
Cannot get the LN2 level (Igor date/time variable of bad data type). |
10 |
Cannot get the LHe level (Igor variable does not exist). |
11 |
Cannot get the LHe level (Igor variable of bad data type). |
12 |
Cannot get the LHe level (Igor data/time variable does not exist). |
13 |
Cannot get the LHe level (Igor date/time variable of bad data type). |
14 |
Cannot get the cold-valve mode (Igor variable does not exist). |
15 |
Cannot get the cold-valve mode (Igor variable of bad data type). |
16 |
Cannot get the cold-valve mode (Igor data/time variable does not exist). |
17 |
Cannot get the cold-valve mode (Igor date/time variable of bad data type). |
18 |
Cannot get the cold-valve pressure (Igor variable does not exist). |
19 |
Cannot get the cold-valve pressure (Igor variable of bad data type). |
20 |
Cannot get the cold-valve pressure (Igor data/time variable does not exist). |
21 |
Cannot get the cold-valve pressure (Igor date/time variable of bad data type). |
22 |
Cannot get the cold-valve power (Igor variable does not exist). |
23 |
Cannot get the cold-valve power (Igor variable of bad data type). |
24 |
Cannot get the cold-valve power (Igor data/time variable does not exist). |
25 |
Cannot get the cold-valve power (Igor date/time variable of bad data type). |
26 |
Cannot get the cold-valve status code (Igor variable does not exist). |
27 |
Cannot get the cold-valve status code (Igor variable of bad data type). |
28 |
Cannot get the cold-valve status message (Igor variable does not exist). |
29 |
Cannot get the cold-valve status message (cannot get string from handle). |
30 |
Cannot get the cold-valve status message (Igor variable of bad data type). |
31 |
The "NOMAD:MagneticField" data folder does not exist. |
32 |
Cannot get the magnetic field (Igor variable does not exist). |
33 |
Cannot get the magnetic field (Igor variable of bad data type). |
34 |
Cannot get the magnetic field (Igor date/time variable does not exist). |
35 |
Cannot get the magnetic field (Igor date/time variable of bad data type). |
36 |
Cannot get the magnetic field setpoint (Igor variable does not exist). |
37 |
Cannot get the magnetic field setpoint (Igor variable of bad data type). |
38 |
Cannot get the magnetic field setpoint (Igor date/time variable does not exist). |
39 |
Cannot get the magnetic field setpoint (Igor date/time variable of bad data type). |
40 |
Cannot get the cryomagnet persistent mode (Igor variable does not exist). |
41 |
Cannot get the cryomagnet persistent mode (Igor variable of bad data type). |
42 |
Cannot get the cryomagnet persistent mode (Igor date/time variable does not exist). |
43 |
Cannot get the cryomagnet persistent mode (Igor date/time variable of bad data type). |
44 |
Cannot get/set the magnetic field Tolerance (Igor variable does not exist). |
45 |
Cannot get the magnetic field Tolerance (Igor variable of bad data type). |
46 |
Cannot get/set the magnetic field Tolerance (Igor date/time variable does not exist). |
47 |
Cannot get the magnetic field Tolerance (Igor date/time variable of bad data type). |
48 |
Cannot determine if the sample is at the expected field (Igor variable does not exist). |
49 |
Cannot determine if the sample is at the expected field (Igor variable of bad data type). |
50 |
Cannot determine if the sample is at the expected field (Igor date/time variable does not exist). |
51 |
Cannot determine if the sample is at the expected field (Igor date/time variable of bad data type). |
52 |
Cannot get the magnet status code (Igor variable does not exist). |
53 |
Cannot get the magnet status code (Igor variable of bad data type). |
54 |
Cannot get the magnet status message (Igor variable does not exist). |
55 |
Cannot get the magnet status message (cannot get string from handle). |
56 |
Cannot get the magnet status message (Igor variable of bad data type). |
57 |
Cannot get/set the magnetic field interface timeout (Igor variable does not exist). |
58 |
Cannot get the magnetic field interface timeout (Igor variable of bad data type). |
59 |
Cannot get/set the magnetic field interface timeout (Igor date/time variable does not exist). |
60 |
Cannot get the magnetic field interface timeout (Igor date/time variable of bad data type). |
61 |
Cannot get the magnetic field status code (Igor variable does not exist). |
62 |
Cannot get the magnetic field status code (Igor variable of bad data type). |
63 |
Cannot get the magnetic field status message (Igor variable does not exist). |
64 |
Cannot get the magnetic field status message (cannot get string from handle). |
65 |
Cannot get the magnetic field status message (Igor variable of bad data type). |
66 |
The "NOMAD:Pressure" data folder does not exist. |
67 |
Cannot get the regulation pressure (Igor variable does not exist). |
68 |
Cannot get the regulation pressure (Igor variable of bad data type). |
69 |
Cannot get the regulation pressure (Igor date/time variable does not exist). |
70 |
Cannot get the regulation pressure (Igor date/time variable of bad data type). |
71 |
Cannot get the pressure setpoint (Igor variable does not exist). |
72 |
Cannot get the pressure setpoint (Igor variable of bad data type). |
73 |
Cannot get the pressure setpoint (Igor date/time variable does not exist). |
74 |
Cannot get the pressure setpoint (Igor date/time variable of bad data type). |
75 |
Cannot get the sample pressure (Igor variable does not exist). |
76 |
Cannot get the sample pressure (Igor variable of bad data type). |
77 |
Cannot get the sample pressure (Igor date/time variable does not exist). |
78 |
Cannot get the sample pressure (Igor date/time variable of bad data type). |
79 |
Cannot get/set the pressure tolerance (Igor variable does not exist). |
80 |
Cannot get the pressure tolerance (Igor variable of bad data type). |
81 |
Cannot get/set the pressure tolerance (Igor date/time variable does not exist). |
82 |
Cannot get the pressure tolerance (Igor date/time variable of bad data type). |
83 |
Cannot determine if the sample is at the expected pressure (Igor variable does not exist). |
84 |
Cannot determine if the sample is at the expected pressure (Igor variable of bad data type). |
85 |
Cannot determine if the sample is at the expected pressure (Igor date/time variable does not exist). |
86 |
Cannot determine if the sample is at the expected pressure (Igor date/time variable of bad data type). |
87 |
Cannot get the press status code (Igor variable does not exist). |
88 |
Cannot get the press status code (Igor variable of bad data type). |
89 |
Cannot get the press status message (Igor variable does not exist). |
90 |
Cannot get the press status message (cannot get string from handle). |
91 |
Cannot get the press status message (Igor variable of bad data type). |
92 |
Cannot get/set the presure interface timeout (Igor variable does not exist). |
93 |
Cannot get the pressure interface timeout (Igor variable of bad data type). |
94 |
Cannot get/set the pressure interface timeout (Igor date/time variable does not exist). |
95 |
Cannot get the pressure interface timeout (Igor date/time variable of bad data type). |
96 |
Cannot get the pressure error code (Igor variable does not exist). |
97 |
Cannot get the pressure error code (Igor variable of bad data type). |
98 |
Cannot get the pressure error message (Igor variable does not exist). |
99 |
Cannot get the pressure error message (cannot get string from handle). |
100 |
Cannot get the pressure error message (Igor variable of bad data type). |
101 |
The "NOMAD:Temperature" data folder does not exist. |
102 |
Cannot get the regulation temperature (Igor variable does not exist). |
103 |
Cannot get the regulation temperature (Igor variable of bad data type). |
104 |
Cannot get the regulation temperature (Igor date/time variable does not exist). |
105 |
Cannot get the regulation temperature (Igor date/time variable of bad data type). |
106 |
Cannot get the temperature setpoint (Igor variable does not exist). |
107 |
Cannot get the temperature setpoint (Igor variable of bad data type). |
108 |
Cannot get the temperature setpoint (Igor date/time variable does not exist). |
109 |
Cannot get the temperature setpoint (Igor date/time variable of bad data type). |
110 |
Cannot get the sample temperature #1 (Igor variable does not exist). |
111 |
Cannot get the sample temperature #1 (Igor variable of bad data type). |
112 |
Cannot get the sample temperature #1 (Igor date/time variable does not exist). |
113 |
Cannot get the sample temperature #1 (Igor date/time variable of bad data type). |
114 |
Cannot get the sample temperature #2 (Igor variable does not exist). |
115 |
Cannot get the sample temperature #2 (Igor variable of bad data type). |
116 |
Cannot get the sample temperature #2 (Igor date/time variable does not exist). |
117 |
Cannot get the sample temperature #2 (Igor date/time variable of bad data type). |
118 |
Cannot get/set the temperature tolerance (Igor variable does not exist). |
119 |
Cannot get the temperature tolerance (Igor variable of bad data type). |
120 |
Cannot get/set the temperature tolerance (Igor date/time variable does not exist). |
121 |
Cannot get the temperature tolerance (Igor date/time variable of bad data type). |
122 |
Cannot determine if the sample is at the resquested temperature (Igor variable does not exist). |
123 |
Cannot determine if the sample is at the resquested temperature (Igor variable of bad data type). |
124 |
Cannot determine if the sample is at the resquested temperature (Igor date/time variable does not exist). |
125 |
Cannot determine if the sample is at the resquested temperature (Igor date/time variable of bad data type). |
126 |
Cannot get the equipment status code (Igor variable does not exist). |
127 |
Cannot get the equipment status code (Igor variable of bad data type). |
128 |
Cannot get the equipment status message (Igor variable does not exist). |
129 |
Cannot get the equipment status message (cannot get string from handle). |
130 |
Cannot get the equipment status message (Igor variable of bad data type). |
131 |
Cannot get/set the temperature interface timeout (Igor variable does not exist). |
132 |
Cannot get the temperature interface timeout (Igor variable of bad data type). |
133 |
Cannot get/set the temperature interface timeout (Igor date/time variable does not exist). |
134 |
Cannot get the temperature interface timeout (Igor date/time variable of bad data type). |
135 |
Cannot get the temperature error code (Igor variable does not exist). |
136 |
Cannot get the temperature error code (Igor variable of bad data type). |
137 |
Cannot get the temperature error message (Igor variable does not exist). |
138 |
Cannot get the temperature error message (cannot get string from handle). |
139 |
Cannot get the temperature error message (Igor variable of bad data type). |