Addresses

Here are the GPIB (IEEE-488) and Ethernet IP addresses commonly used by the Advanced Neutron Environment team to remotely control sample environment equipment. The IP addresses are used on a Local Area Network of each instrument. SANE electronics are not visible from the outside world to prevent network issues.

Main Controllers

Controller GPIB Ethernet Comment

ILL SANE Unified controller (IGOR Pro from WaveMetrics)

-

192.168.248.001

See Procedure files

ILL Auto-ID controller

-

192.168.248.002

Standard TCP/IP interface

ILL Auto-ID controller

-

192.168.248.003

ModBus-TCP interface

TCP/IP to RS232/422/485 converter Model ARC-1000 (primary)

-

192.168.248.004

-

TCP/IP to RS232/422/485 converter Model ARC-1000 (secondary)

-

192.168.248.005

-

NI GPIB-Enet/100 or GPIB-Enet/1000 interfaces

0 [D]

192.168.248.200

Drivers available from NI

ICS Electronics Model 4896 GPIB to Serial interface

5

-

Plugged to NI GPIB-ENET Interface

CCD Camera Data Acquisition

-

192.168.248.252 

-

NOMAD Instrument Control workstation

-

192.168.248.253 [D]

-

[D] Factory settings i.e. default GPIB or IP addresses

High Magnetic Field Controllers

Controller GPIB Ethernet Comment

Oxford Instruments IPS 120-10 magnet power supply

25 [D]

-

Plugged to NI GPIB-ENET Interface

MOXA NPort 5110 for IPS 120-10 magnet power supply

-

192.168.248.025

RS-232 / Ethernet Gateway

Oxford Instruments Mercury iPS magnet power supply

-

192.168.248.026

-

American Magnetics 4Q06250PS-430 magnet power supply

-

192.168.248.027

-

HTS-110 Magnet System Supervisor

-

192.168.248.028

-

Kepco BOP 6-125 ME power supplies (master)

-

192.168.248.029

-

17 Tesla Birmingham magnet controller

-

192.168.248.030

-

40 Tesla pulsed magnet controller

-

192.168.248.031

-

[D] Factory settings i.e. default GPIB or IP addresses

High Temperature Controllers

Controller GPIB Ethernet Comment

ILL Power rack for resistive furnaces

-

192.168.248.205 [D]

ModBus-TCP link - see ModBus XOP

ILL Power rack for anvils of Paris-Edinburgh cells (Eurotherm NanoDAC)

-

192.168.248.224

ModBus-TCP link - see ModBus XOP

ILL Power rack for anvils of Paris-Edinburgh cells (ICPCON ET 7218Z)

-

192.168.248.235

ModBus-TCP link - see ModBus XOP

AMETEK 1200SE Ethernet Gateway (MOXA Sport 5110)

-

192.168.248.116

RS-232 / Ethernet

[D] Factory settings i.e. default GPIB or IP addresses

High Pressure Controllers

Controller GPIB Ethernet Comment

SITEC 1 GPa liquid pressure regulators

-

192.168.248.213

ModBus-TCP link - see ModBus XOP

ILL 700 MPa He gas pressure regulator (Eurotherm 2704)

-

192.168.248.215

ModBus-TCP link - see ModBus XOP

ILL 700 MPa He gas pressure regulator (ICPCON, Valves positioning)

-

192.168.248.216

-

ILL 700 MPa He gas pressure regulator (Magelis, Multiplier HMI)

-

192.168.248.217

-

ILL 700 MPa He gas pressure regulator (Magelis, Compressor HMI)

-

192.168.248.218

-

ILL 200 MPa He gas pressure regulators

-

192.168.248.223

ModBus-TCP link - see ModBus XOP

ILL 700 MPa liquid pressure stick controllers

-

192.168.248.225

ModBus-TCP link - see ModBus XOP

SITEC 1 GPa He gas controllers (Eurotherm mini8)

-

192.168.248.232

ModBus-TCP link - see ModBus XOP

SITEC 1 GPa He gas controllers (Panel PC)

-

192.168.248.233

-

ELMAC Press

-

192.168.248.237

-

Autofrettage Controller

-

192.168.248.240

-

[D] Factory settings i.e. default GPIB or IP addresses

Low Temperature Controllers

Controller GPIB Ethernet Comment

LakeShore Model 340 Main controller

12 [D]

-

Plugged to NI GPIB-ENET Interface

MOXA NPort 5110 for LakeShore Model 340 Main controller

-

192.168.248.018

RS-232 / Ethernet Gateway on TCP port 4001

LakeShore Model 336 Main controller

-

192.168.248.012

TCP port 7777

LakeShore Model 340 Secondary controller

13

-

Plugged to NI GPIB-ENET Interface

MOXA NPort 5110 for LakeShore Model 340 Secondary controller

-

192.168.248.019

RS-232 / Ethernet Gateway on TCP port 4001

LakeShore Model 336 Secondary controller

-

192.168.248.013

TCP port 7777

LakeShore Model 370 AC Resistance Bridge

14

-

Plugged to NI GPIB-ENET Interface

LakeShore Model 372 AC Resistance Bridge

-

192.168.248.014

TCP port 7777

RTA Gateway for LakeShore Model 340 controller

-

192.168.248.015

ModBus-TCP interface

RTA Gateway for LakeShore Model 336 controller

-

192.168.248.016

ModBus-TCP interface

RTA Gateway for LakeShore Model 370

-

192.168.248.017

ModBus-TCP interface

ILL LN2 level monitor — Main cryostat

-

192.168.248.201 [D]

ModBus-TCP link - see ModBus XOP

ILL LHe level monitor — Main cryostat

-

192.168.248.202 [D]

ModBus-TCP link - see ModBus XOP

ILL Cold-valve controller — Main cryostat

-

192.168.248.203 [D]

ModBus-TCP link - see ModBus XOP

ILL He Recondensing Controller

-

192.168.248.204 [D]

ModBus-TCP link - see ModBus XOP

ILL LN2 level monitor — Beryllium filter, Cryoflipper

-

192.168.248.209

ModBus-TCP link - see ModBus XOP

ILL LHe level monitor — Cryoflipper

-

192.168.248.210

ModBus-TCP link - see ModBus XOP

ILL Gas handling system for Dilution inserts (PLC)

-

192.168.248.230

ModBus-TCP link - see ModBus XOP

ILL Gas handling system for Dilution inserts (Panel PC)

-

192.168.248.231

ModBus-TCP link - see ModBus XOP

ILL Gas handling system of SuperSUN (PLC)

-

192.168.248.236

ModBus-TCP link - see ModBus XOP

ILL T-gradient Monochromator of IN13 (PLC)

-

192.168.248.238

ModBus-TCP link - see ModBus XOP

[D] Factory settings i.e. default GPIB or IP addresses

Soft Matter & Biology Controllers

Controller GPIB Ethernet Comment

In-situ Chromatography SEC-SANS — Selector H (6 Channels, 1 position)

-

192.168.248.100

-

In-situ Chromatography SEC-SANS — Pump H (BlueShadow 40P)

-

192.168.248.101

-

In-situ Chromatography SEC-SANS — Selector D (6 channels, 1 position)

-

192.168.248.102

-

In-situ Chromatography SEC-SANS — Pump D (BlueShadow 40P)

-

192.168.248.103

-

In-situ Chromatography SEC-SANS — Ante-valve (3 channels, 2 positions)

-

192.168.248.104

-

In-situ Chromatography SEC-SANS — Autosampler (Spark ALIAS)

-

192.168.248.105

-

In-situ Chromatography SEC-SANS — Post-valve (3 channels, 2 positions)

-

192.168.248.106

-

In-situ Chromatography SEC-SANS — Spectrometer (Smartline UV Detector 2600)

-

192.168.248.107

-

In-situ Chromatography SEC-SANS — Fraction Collector (Foxy R1)

-

192.168.248.108

-

In-situ Conductivity meter (SevenExcellence)

-

192.168.248.109

-

ILL Beryllium filter

-

192.168.248.110

ModBus-TCP link - see ModBus XOP

Relative Humidity & Dew Point — Comet System T3510

-

192.168.248.111

ModBus-TCP link - see ModBus XOP

SANS Sample Changer #1 — Quantum Northwest SuperNeutron 600

-

192.168.248.112

RS-232 / Ethernet Gateway

ILL Humidity Generator

-

192.168.248.113

ModBus-TCP link - see ModBus XOP

ILL Instrument Parameter Monitor

-

192.168.248.114

ModBus-TCP link - see ModBus XOP

Harward 33 DDS syringe pump

-

192.168.248.115

RS-232 / Ethernet Gateway

Chiller / Thermostatic bath — Main controller

-

192.168.248.206

-

Chiller / Thermostatic bath — Secondary controller

-

192.168.248.207

-

Chiller / Thermostatic bath — Oil

-

192.168.248.241

-

ILL Relative Humidity & Temperature controller

-

192.168.248.208 [D]

ModBus-TCP link - see ModBus XOP

Cordouan/ILL ex-situ dynamic light scattering system

-

192.168.248.226

CAMEO Server

Cordouan/ILL in-situ dynamic light scattering system

-

192.168.248.227

CAMEO Server

ILL Adsorption troughs

-

192.168.248.228

ModBus-TCP link - see ModBus XOP

ILL Langmuir troughs

-

192.168.248.229

ModBus-TCP link - see ModBus XOP

Shear cell (motor drive)

-

192.168.248.234

-

ILL Solid/Liquid Cells (pumps and valves)

-

192.168.248.239

NetCom Plus 811 POE RS-232 / Ethernet Gateway

[D] Factory settings i.e. default GPIB or IP addresses

Generic Analog/Digital Interfaces

Controller GPIB Ethernet Comment

ICS Electronics Model 4861B GPIB to Analog interface

4 [D]

-

Plugged to NI GPIB-ENET Interface

Basler ace GigE camera #1

-

192.168.248.151

GigE Vision standard

Basler ace GigE camera #2

-

192.168.248.152

GigE Vision standard

Basler ace GigE camera #3

-

192.168.248.153

GigE Vision standard

Basler ace GigE camera #4

-

192.168.248.154

GigE Vision standard

Basler ace GigE camera #5

-

192.168.248.155

GigE Vision standard

Ethernet I/O Module with 7-ch RTD Inputs (Model ET-7215)

-

192.168.248.211

ModBus-TCP link - see ModBus XOP

Ethernet I/O Module with 8-ch analog inputs (registers 30.000 to 30.007),
4-ch digital output (Model ET-7217)

-

192.168.248.212

ModBus-TCP link - see ModBus XOP

Display panel for Model ET-7215 above

-

192.168.248.219

ModBus-TCP link - see ModBus XOP

Display panel for Model ET-7217 above

-

192.168.248.220

ModBus-TCP link - see ModBus XOP

Ethernet I/O Module with 10-ch Thermocouple inputs, 3-ch digital output (Model ET-7219Z)

-

192.168.248.221

ModBus-TCP link - see ModBus XOP

Display panel for Model ET-7219Z above

-

192.168.248.222

ModBus-TCP link - see ModBus XOP

[D] Factory settings i.e. default GPIB or IP addresses