enough to continue heating. Find out more Std Furnace Controllers 4-Circle Furnace Controllers PE Cell Heater Controller (png - 54 Ki) We also provide a similar but more compact power supply for regulating
Recherche
Recherche de cell.
417 résultats ont été trouvés en 2 millisecondes.
Affiche les résultats de 101 à 110 sur 417.
Pages
Pertinence: 23%
Pages
Power rack for anvils of Paris-Edinburgh cells (Eurotherm NanoDAC) - 192.168.248.224 ModBus-TCP link - see ModBus XOP ILL Power rack for anvils of Paris-Edinburgh cells (ICPCON ET 7218Z) - 192.168.248.235 ... Langmuir troughs - 192.168.248.229 ModBus-TCP link - see ModBus XOP Shear cell (motor drive) - 192.168.248.234 ILL Solid/Liquid Cells (pumps ...
Pertinence: 32%
Pages
enter a setpoint of 0 and close the valve. Plug the capillary into the high-pressure cell or press, open the "Sample Cell" valve. Procedure for using the controller With the arrow keys of the Eurotherm controller ... when the temperature is high enough to truly release the pressure in the cell. If the temperature is too low, you must warm up the ce ...
Pertinence: 47%
Pages
This compact cell is made from a hardened beryllium-copper alloy. It has a Ø5 x 20 mm sample volume. It uses Fluorinert as the pressure medium. The pressure is generated using a hydraulic press, then locked
Pertinence: 100%
Pages
stick #1 is used with an aluminium 3kbar pressure cell., the stick #4 with a 5kbar gas pressure cell, the #10 and #12 with a 7kbar liquid pressure cell and the stick #11 with a 7 kbar capillary allowing
Pertinence: 45%
Pages
5.70 Ki) Sensor Samp. (bottom of cell) Cernox CX1050 Serial number X87164 Calibration ILL 2013-2 Interpol. Table download (txt - 5.65 Ki) Sensor at top of cell Cernox CX1050 Serial number X163165 Calibration ... With non-magnetic VX-5 Paris-Edinburgh cell Type Closed-cycle Tmin 1.8K Tmax 320K Instrument Pool Sensor Reg. Cernox CX1050 Serial number ...
Pertinence: 47%
Pages
Ki) Sensor Samp. (bottom of cell) Cernox CX1050 Serial number X98454 Calibration ILL 2015-1 Interpol. Table download (txt - 5.65 Ki) Sensor at top of cell Cernox CX1050 Serial number X98453 Calibration ... With VX-1 or VX-5 Paris-Edinburgh cell Type Closed-cycle Tmin 1.8K Tmax 320K Instrument Pool Sensor Reg. Cernox CX1050 Serial number X98452 ...
Pertinence: 47%
Pages
Pertinence: 100%
Pages
This cell is made from the aluminium alloy 7049-T6. It has a Ø6 x 65 mm, i.e. 1.85 ml, sample volume and uses helium as the pressure medium. The pressure is generated using a standard gas compressor. For ... , it may be used on a polarised neutron instrument or inside a cryomagnet. Dimensions of the TiZr cell in the beam. (pdf - 2.35 Mi)
Pertinence: 100%
Pages
This cell is made from TiZr alloy . It has a Ø6 x 65 mm, i.e. 1.85 ml, sample volume and uses helium as the pressure medium. The pressure is generated using a standard gas compressor. For powders, the ... , it may be used on a polarised neutron instrument or inside a cryomagnet. Dimensions of the TiZr cell in the beam (pdf - 0.92 Mi)
Pertinence: 100%