bar•l/h. On the 2rd photo one can see in the heads of 7 small compressed air valves (3 are vertical and in the background), a technology developped by the ILL for its cryostats. On the right, the liquid nitrogen ... COW before TYREX A very first test of a 3 He filter was performed at the ILL on D3 in 1990 [1] using the spin-exchange optical pumping ...
Search
Searched for ill7.
Found 110 results in 3 milliseconds.
Displaying results 1 to 10 of 110.
Pages
Relevance: 11%
Pages
D3 without loss of polarisation. W. Heil and H. Humblot carry the filter to the ILL reactor hall, where A. Leadbetter (ILL Director) is anxiously waiting for them at D3. F. Tasset, H. Humblot and W. Heil ... the historical experiment of 1996 [1] when the first spin filter was produced and then tested on the ILL neutron diffractometer D3. See how ...
Relevance: 12%
Pages
spectroscopy measurements were performed at ILL Instruments IN5 (TOF spectrometer) and IN11 (neutron spin-echo spectrometer). “It’s amazing to see how ILL’s powerful spectrometers allow us to follow the ... translations and rotations of triphenylphosphine on graphite. Commun Chem 7 , 78 (2024). https://doi.org/10.1038/s42004-024-01158-7 More info: ...
Relevance: 13%
Pages
► instrument responsible on D7 and D007 Main areas of expertise : E-mail wildes(at)ill.fr Location Building ILL 4 - Office 101 Phone Phone : +33 (0)4 76 20 70 37 Instr. phone +33 (0)4 76 20 Digital vcard ... Diplôme d'Habilitation à Diriger des Recherches, Ecole Normale Supèrieure de Lyon, France History at ILL: 1997 - 1998: Co-responsible for IN20 ...
Relevance: 14%
Pages
results of experiments performed at the ILL, do not hesitate to submit them. The deadline for submitting contributions is usually 1 October every year. The format of the ILL annual report is 25 cm x 20 cm. Please ... provide a photo of the ILL instrument if available, but do not hesitate to submit a photo of your choice if relevant. Contact us for ...
Relevance: 11%
Pages
copper (111), (224) Bragg angle 2θ m 42.7°, 70° or 90° wavelength 0.8 < λ/Å <2.4 Collimation before monochromator 60' (natural) Sample max. beam size 10 mm flux 10 7 ... 10 8 n cm -2 s -1 angular range -60° ... take-off angle of 90° - any one of four monochromators may be rotated into diffracting position using an ILL box-shaped monochromator mount ...
Relevance: 11%
Pages
Energy range 1.3x10 -5 ... 0.01 meV (10 Å) 2x10-4 ... 0.15 meV (4 Å) Momentum transfer range 0.03 ... 2.7 Å -1 (4 Å) 0.02 ... 1.35 Å -1 (8 Å) Large angle detector (option IN11C) Detector solid angle 30° x 1 ... H1 parallel resulting in higher polarization at small scattering angles. The sample stage takes all ILL standard sample environments ...
Relevance: 9%
Pages
3.1 m 46.10 mm -> 38.0 mm from 3.1 to 1.6 m guide-to-sample distances 1.6, 3.1, 4.1, 5.6, 6.7, 7.7, 10.2, 12.7, 15.2, 16.5, 17.8, 20.3, 22.8, 24.8, 26.9, 29.4, 31.9, 35.2 m (18 discrete distances) 4 va ... (39 m) λ = 2.2 nm selector rotation normal to n-beam possible minimum wavelength at rotation -7° -7° to + 7° λ = 0.32 nm Collimation 17 guide ...
Relevance: 14%
Pages
Guide hall n°1, ILL7, cold neutron guide H171 (Vertical Neutron Source) guide section 80 x 30 mm2 (w x h) Instrument Data beam size at sample 40 x 10 mm 2 incident wavelength range 2 - 30 Å scattering ... 0.62˚ angles deflected beam -2.5˚ < θ < 3.8˚ (horizontal) constant wavelength resolution δλ/λ [0.8-7.0%] elastic Q-range (down) 0.0045 – 0.42 Å ...
Relevance: 15%
Pages
physics, neutron powder diffraction, magnetic structure determination E-mail ritter(at)ill.fr Location Building ILL 4 - Office 143 Phone Phone : +33 (0)4 76 20 74 60 Instr. phone +33 (0)4 76 20 7386 +33 ... 100405 ( R ) “Ferromagnetically coupled Shastry-Sutherland quantum spin singlets in (CuCl)LaNb 2 O 7 ” C. Tassel, J. Kang, C. Lee, O. ...
Relevance: 5%
