from value1 to value2. e.g. SCAN OME 5 15 .17 (or SOM 5 15 .17) If value1 > value2 the routines will default to a centred stepped scan about value1 of width value2. ie scans from value1- (value2/2) to value1 ... > scan 2theta 100 120 1 1000 0 1 Scan --> 2theta Position 100 -> 120 delta 1 steps 2 Numor 710883 Step 2theta Time Monitor1 Detector ...
Search
Searched for 2.1 - 1.5.
Found 365 results in 3 milliseconds.
Displaying results 91 to 100 of 365.
Pages
Relevance: 46%
Pages
Table download (LK336) (txt -5.68 Ki) download (LK340) (txt -5.67 Ki) (svg - 642 Ki) (svg - 493 Ki) (svg -1.31 Mi) ... Ø70 Tmin 1.5K Tmax 320K Instrument IN6 - SHARP Sensor Regul. Cernox CX1050 Serial number X48267 Calibration ILL 2007-7 Interpol. Table download (LK336) (txt -5.70 Ki) download (LK340) (txt -5.70 Ki) Sensor ... Sensor Samp. #1 ...
Relevance: 46%
Pages
dedicated to D3 - stick #2 is for TU experiments Type ILL VTI Tmin 1.5K Tmax 300K Instrument D3 Sensor Regul. Cernox CX1050 Serial number X05167 Calibration OIS Interpol. Table Download (txt -5.67 Ki) Sensor ... r01: 5.5 A/min between 0 and 45 A r02: 4 A/min between 45 and 100 A r03: 2 A/min between 100 and 110 A r04: 0.5 A/min between 110 and ...
Relevance: 46%
Pages
Table download (txt -5.65 Ki) Sensor Samp. #2 Cernox CX1050 Serial number X163173 Calibration ILL 2021-1 Interpol. Table download (txt -5.62 Ki) (svg - 482 Ki) (svg - 341 Ki) (svg - 484 Ki) ... Type Orange Ø50 Tmin 1.5K Tmax 320K Instrument IN8 Sensor Regul. Cernox CX1050 Serial number X163155 Calibration ILL 2021-1 Interpol. Table download (txt ...
Relevance: 46%
Pages
ILL 2019-1 Interpol. Table download (txt -5.65 Ki) Sensor Samp. #2 Cernox CX1050 Serial number X113921 Calibration ILL 2020-3 Interpol. Table download (txt -5.70 Ki) (svg - 491 Ki) (svg - 491 Ki) (svg ... Type Orange Ø50 Tmin 1.5K Tmax 320K Instrument IN8 Sensor Samp. #1 Cernox CX1050 Serial number X144619 Calibration ILL 2019-1 Interpol. Table ...
Relevance: 46%
Pages
height x 5 cm width Monochromators size: 20 cm height x 18 cm width variable vertical focussing crystal spacing d/Å Ei range (meV) ΔEi (meV) Cu(220) 1.278 [26-500] 2-3% Ei Cu(331) 0.829 [67-500] 1.5-2% Ei Si(311) ... [16.5-60] 0.8 Si(111) [4.5-20] 0.8 Collimation Boron coated collimators α2, α3, α4 = 20', 30', 40', 60' Sample beam size at sample ...
Relevance: 46%
Pages
Download (txt -5.70 Ki) Sensor Samp. #1 Cernox CX1050 Serial number X144631 Calibration ILL 2009-1 Interpol. Table Download (txt -5.68 Ki) Sensor Samp. #2 RhFe Serial number 8619 Calibration - Interpol. ... The sample stick #2 goes into a heating insert for reaching 650K. Type Closed-cycle Ø49 Tmin 3.5K Tmax 650K Instrument D2B Sensor Regul. ...
Relevance: 46%
Pages
Table download (txt -5.65 Ki) Sensor Samp. #2 Cernox CX1050 Serial number X98455 Calibration/th> ILL 2015-1 Interpol. Table download (txt -5.65 Ki) (svg - 281 Ki) (svg - 273 Ki) (svg - 231 Ki) ... Type Orange Ø50 Tmin 1.5K Tmax 320K Instrument Pool Sensor Regul. Cernox CX1050 Serial number X46953 Calibration ILL 2007-2 Interpol. Table download ...
Relevance: 46%
Pages
design - 80 bar max. Type Stick for 213ILCC70 Tmin 1.5K Tmax 320K Instrument IN1 Lagrange Sensor Samp. #2 RhFe Serial number F353 Calibration ILL #2020-1-RhFe Interpol. Table Download (txt -5.34 Ki) Sensor ... Sensor Samp. #1 Cernox CX1050 Serial number X48300 Calibration ILL #2011-4 Interpol. Table Download (txt -5.62 Ki) (svg - 265 Ki) (svg - ...
Relevance: 46%
Pages
Type Orange Ø50 Tmin 1.5K Tmax 320K Instrument D2B Sensor Regul. Cernox CX1050 Serial number X163164 Calibration ILL 2021-1 Interpol. Table download (txt -5.62 Ki) Sensor Samp. #2 Cernox CX1050 Serial ... Serial number X47019 Calibration ILL 2007-3 Interpol. Table download (txt -5.67 Ki) (svg - 482 Ki) (svg - 272 Ki)
Relevance: 46%