stick #1 is used with an aluminium 3kbar pressure cell., the stick #4 with a 5kbar gas pressure cell, the #10 and #12 with a 7kbar liquid pressure cell and the stick #11 with a 7 kbar capillary allowing
Recherche
Recherche de cell.
429 résultats ont été trouvés en 6 millisecondes.
Affiche les résultats de 81 à 90 sur 429.
Pages
Pertinence: 43%
Pages
within each unit cell of the crystal, and whose appearance coincides with the onset of the pseudogap. This magnetic order could be the result of loop currents flowing within the unit cells, generating staggered ... Instrument: D7 - Diffuse Scattering Spectrometer Re.: Intra-unit-cell magnetic correlations near optimal doping in YBa2Cu3O6.85. ...
Pertinence: 43%
Pages
Reflectorch, un progiciel d'apprentissage automatique Python développé à l'Université de Tübingen. Cela a été rendu possible grâce à une étroite collaboration entre les services de contrôle des instruments
Pertinence: 23%
Pages
of cell (t1) params[3]=polarizer inefficiency (p1) params[4]=gas pressure ([3He]) params[5]=wavelength (lambda) params[6]=first flipper efficiency (f1) params[7]=second flipper efficiency (f2) Cell thickness ... OPTIONAL VARIABLES: main=a string with the numbers for a measurement of the main beam, with an empty cell water=the number of the ...
Pertinence: 21%
Pages
sample changer, 10 to 22 positions electromagnets up to 2 Tesla cryostats (4 to 300 K) Couette shear cell (sample volume 4.5/7.5 ml, max. G = 12000 s -1 ) 3. Data acquisition and NOMAD The data acquisition ... whole detector behaves like a single detector with a dead time of 2.06 microsec. Corrected counts per cell are obtained by I(x,y,true) = ...
Pertinence: 13%
Pages
though the cell to be approximately 1/2 that of the fly-past beam around the sides of the cell. Interestingly, the radiographic image even shows attenuation contrast due to the quartz cylindrical cell walls ... group will deliver a polarised cell, pressurised as specified by the local contactor users. The gas pressure determines the cell opacity, ...
Pertinence: 46%
Pages
beamstop width or diameter [mm] 76 beamstop height or 0. [mm] 77 ISUM X1 [cell #] 78 ISUM X2 [cell #] 79 ISUM Y1 [cell #] 80 ISUM Y2 [cell #] 81 shear speed [1/min] x 82 magnetic field [Tesla] 83 pressure [Pa] ... 46 47 48 49 50 further parameters stored with the data 51 beam centre address X0 [cell#] x 52 beam centre address Y0 [cell#] x 53 ...
Pertinence: 43%
Pages
Added magnetic form factors for rare-earth elements Possibility to hide the unit cell axes or to plot less than the 1st unit cell in order to focus e.g. on particular layers in a structure The tutorial videos ... normal-beam, minimum-tilt and cryocradle geometries correction of polarization data for 3He spin-filter cell efficiency simple creation ...
Pertinence: 34%
Pages
cosmétique et des soins capillaires, car elles nous aident à comprendre nos formulations en détail. Cela nous permet de les optimiser au niveau moléculaire", ajoute Gustavo S. Luengo, chercheur chez L'Oréal
Pertinence: 27%
Pages
positifs (cations) et plus d'un type d'ion négatif (anions) au sein d'une seule structure cristalline. Cela offre une plus grande capacité d'ajustement ( tunability ) de leurs propriétés physiques et chimiques ... composés conventionnels à anion unique. La classe de tels composés la plus largement étudiée est celle des oxyhydrures, contenant à la ...
Pertinence: 40%
