detector) Energy range: ~40 keV - 8 MeV Efficiency at 1.4 MeV = 3% (from singles 152Eu). Add-back factor at 1.4 MeV = 1.17 Gas-Filled Magnet The ambitious goal of FIPPS is to combine a high resolution gamma-ray ... the H22 guide is collimated to a halo-free pencil beam of 1.5cm diameter. The neutron beam intensity at the target position is of 10 8 ...
Recherche
Recherche de 1'".
1023 résultats ont été trouvés en 3 millisecondes.
Affiche les résultats de 161 à 170 sur 1023.
Pages
Pertinence: 17%
Pages
10.6). Version 1.01 - October 2009 Help flag bug fixed. Release based upon omniORB 4.1.4. 32-bit version compatible with Leopard (Mac OS X 10.5) and Snow Leopard (Mac OS X 10.6). Version 1.00 - January 2008 ... provided by the get…Error() methods. Version 1.02 for Mac OS X and Igor Pro 5.02+ (Universal Binary XOP, omniORB, client): (dmg - 11.29 Mi) ...
Pertinence: 17%
Pages
(100 Å) : about 10 5 cm -2 s -1 (m/s) -1 (= 0.4 x 10 5 cm -2 s -1 Å -1 ) UCN (4 ports) beam sizes: 4 x 4, 7 x 7, 10 x 10 and 14 x 10 cm 2 total flux: 2.6 x 10 4 cm -2 s -1 for v z < 6.2 m/s (3.3 x 10 4 ... homogeneous for v > 40 m/s. The flux at v = 40 m/s (100 Å) is about 10 5 cm -2 s -1 (m/s) -1 (= 0.4 x 10 5 cm -2 s -1 Å -1 ). The 4 UCN beams ...
Pertinence: 17%
Pages
Number of exchangeable protons C CH CH2 CH3 N NH NH2 NH3 O OH 0. 0. 0. 0. 0. 1. 2. 3. 0. 1. S SH P FE CU CA MG MN ZN N(Histidine) 0. 1. 0. 0. 0. 0. 0. 0. 0. 0.5 - by default, Cryson searches for the contrast ... Mb RAM and VGA or SVGA graphic card. Operating systems: DOS/Win3.1/Win95/WinNT. The program works in a full-screen DOS window. Under Win3. ...
Pertinence: 17%
Pages
Type Orange Ø50 Tmin 1.5K Tmax 320K Instrument ThALES Sensor Samp. #1 Cernox CX1050 Serial number X47183 Calibration ILL 2007-4 Interpol. Table download (txt - 5.65 Ki) Sensor Samp. #3 Cernox CX1050 Serial ... Serial number X144632 Calibration ILL 2019-1 Interpol. Table download (txt - 5.68 Ki) Sensor Regul. Cernox CX1050 Serial number X144614 ...
Pertinence: 17%
Pages
(txt - 5.70 Ki) Sensor Samp. #1 Cernox CX1050 Serial number X144611 Calibration ILL 2019-1 Interpol. Table download (txt - 5.68 Ki) Sensor Samp. #2 Cernox CX1050 Serial number X139469 Calibration ILL 2018-3 ... ype Orange Ø70 Tmin 1.5K Tmax 320K Instrument IN6 - SHARP Sensor Regul. Cernox CX1050 Serial number X48267 Calibration ILL 2007-7 Interpol. ...
Pertinence: 17%
Pages
0.02 - 1 Å -1 with the detector centred (SANS setup with beamstop) and 0.02 - 2 Å -1 with the detector positioned off the direct beam (SANS-WANS setup). The q-max remains unchanged at 2.5 Å -1 and can ... (115°) mosaicity 0.4° (HOPG) and 1.5° (Rb-int) Beryllium filter cooling liquid nitrogen cut-off 3.95 Å path length 100 mm efficiency λ/2 < 0.1 % ...
Pertinence: 17%
Pages
----------- Angular units in the input file : 4*pi*sin(theta)/lambda [1/angstrom] (1) 4*pi*sin(theta)/lambda [1/nm ] (2) < 2 >: 1 =QUE= --------------------------------------------------- The working units ... the USER mode. --------------------------------------------------- Particle symmetry (P1/P2/P3/P4/P222) ... < P1 >: p1 =QUE= ...
Pertinence: 17%
Pages
Dual-exchanger, Vanadium tail Type Orange Ø49 Tmin 1.5K Tmax 600K Instrument D4 , IN1 Sensor Regul. (bottom) RhFe Serial number E794 Calibration ILL 2017-4-RhFe Interpol. Table Download (txt - 5.28 Ki) ... Calibration ILL 2017-4-RhFe Interpol. Table Download (txt - 5.31 Ki) Sensor Samp. #1 RhFe Serial number F357 Calibration ILL #2020-1 Interpol. ...
Pertinence: 17%
Pages
0 100 4963 Fill command 0 1 4976 Fill timeout value in min (default: 30min) 0 100 11272 Fill timeout error status 0 1 11273 Auto-run-down status 0 1 10265 Firmware version 1 10 4977 Electrical and operating ... contact us. Release History 1.00 - Initial release 1.01 - Modified the pages for simplifying the use of the controller. 1.02 - Fixed an ...
Pertinence: 17%
