update 15/05/2024 (v1.7.2): optional Lorentz correction when exporting a fit range of peaks, bugfix in application of Lorentz factor update 20/06/2024 (v1.7.3): adapted to new D3 Numor format, fixes the ... eigen.tuxfamily.org ). Features open Numors containing any type of scan (including D10 Flatcone) visualization of 2D detector images open *.ans ...
Search
Searched for D7.
Found 282 results in 4 milliseconds.
Displaying results 81 to 90 of 282.
Pages
Relevance: 15%
Pages
sizes: 4 x 4, 7 x 7, 10 x 10 and 14 x 10 cm 2 total flux: 2.6 x 10 4 cm -2 s -1 for v z < 6.2 m/s (3.3 x 10 4 for v z < 7 m/s) calculated density : 87 and 110 cm 3 for v < 6.2 and v < 7 m/s, respectively ... are high quality Ni surfaces. These neutron guides transmit a beam of about 7 x 7 cm 2 with wavelengths 20 < λ < 400 Å to level D. In the ...
Relevance: 15%
Pages
and instrument configurations, a minimum reflected signal of 5 x 10 -7 or 1 x 10 -6 after background subtraction can be obtained for D 2 O or H 2 O, respectively. Without taking further measures to reduce ... 5-A rms roughness. Typical counting times using 80x50 mm crystals, 7% wavelength resolution and a 20-A frame overlap mirror are 45 min in D 2 ...
Relevance: 15%
Pages
required for the H15 triple guide and its instruments suite: D007, D11+, SHARP+ and SAM. As critical prerequisite for restarting the user programme in ILL7, namely the construction of the new cold guide casemate ... shielding for D10+ and XtremeD along with the instrument zone separation walls. By the beginning of the summer, work on the new H1 ...
Relevance: 15%
Pages
(39 m) λ = 2.2 nm selector rotation normal to n-beam possible minimum wavelength at rotation -7° -7° to + 7° λ = 0.32 nm Collimation 11 guide sections (computer controlled) uncoated glass guides (Swiss ... loss at 66 kHz per tube, at 225 kHz) Instrument characteristics & description D11 - a "microscope" for exploring the nanoworld D11 is the ...
Relevance: 15%
Pages
Proposition d’un nouveau software pour le diffractomètre 4-cercles rayons X Siemens LI4” Filhol A. Thomas M. (1975) ILL75F242T " Proposition d’un nouveau software pour les diffractomètres neutrons D8, D9, D10” ... Abstract "D19A and B: design and construction of a 4-circle neutron diffractometer with two-dimensional PSDs" Thomas M., Stansfield R.F. ...
Relevance: 15%
Pages
< 80ºC 5 (solid/liquid) - 7 (solid/air) position sample changer Liquids changer Humidity chamber Off-line Langmiur-Blodgett preparation Quartz window vertical cryomagnet < 7 T, 1.5 - 300 K (Maximum 25 ... This flux, combined with the low instrumental background, allows reflectivities down to 10 -7 to be measured. D17 operates in four modes, ...
Relevance: 15%
Pages
incident energy (meV) 2.08 2.08 7.63 2.56 flux at the sample (n/cm 2 /s) @ 58 MW HF: 6.0 10 5 LB: 8.7 10 4 t.b.d. HF: 1.2e5 t.b.d., but sensibly lower than Si(111) t.b.d. analysers Si(111): small angle ... energy transfer (μeV) ±31 ±31 ±59 t.b.d., ~ ± 250 / ±70 / -850...1000 for Si(111) / Si(111) high rep. rate / Si(311) Q-range (Å -1 ) 0.1 - 1.8 ...
Relevance: 15%
Pages
Research Scientist E-mail avorobiev(at)ill.eu Office 17 - ILL7/22 Phone +33 (0)4 76 20 72 89 Responsibilities Instrument scientist D17 Science Journal Publications Publications Personal Section
Relevance: 15%
Pages
and multilayers - Inelastic scattering in four-circle geometry D19 Thermal neutron diffractometer for single-crystal and fibre diffraction D19 - Single crystal: Organometallic complexes; Hydrogen-bonded ... polymers - Polycrystals: Texture Alpine rocks and magnetic polymers D23 Thermal neutron two-axis diffractometer for single-crystals D23 - ...
Relevance: 15%