187ILHP49 unavailable 1.5 - 320 ? Ø49 188ILHP49 unavailable 1.5 - 320 ? Ø49 221ILHP49 unavailable 1.5 - 320 0.5 Ø49 with Nb cell adjustable in height 190ILHP49 unavailable 1.5 - 320 1.5 Ø49 Stainless steel ... cell, with heated capillary 63ILHV70 #11.5 - 320 2.5 Ø70 for gas pressure cell 02PGAL15 216ILHP49 unavailable 1.5 - 320 3 Ø49 with CuBe gas ...
Search
Searched for 1'".
Found 1045 results in 2 milliseconds.
Displaying results 81 to 90 of 1045.
Pages
Relevance: 19%
Pages
Guide hall n 1, thermal guide H24 Guide Divergence - supermirror (m=2) 6.9 mrad Å Monochromator Vertically focussing and continuously variable pyrolytic graphite 1.8 < λ < 6 Å Cu (200) 1.1 < λ < 3 Å incident ... -3 absolute energy resolution δE 0.02 THz at ki = 1.55 Å -1 λ/2 contamination < 2 x 10 -4 at 1.26 Å with Cu monochromator and no analyser ...
Relevance: 19%
Pages
RhFe Serial number F359 Calibration ILL #2020-1-RhFe Interpol. Table Download (txt - 5.31 Ki) Sensor Samp. #1 RhFe Serial number E459 Calibration ILL #2016-1 RhFe Interpol. Table Download (txt - 5.42 Ki) ... Dual-exchanger, Vanadium tail Type Orange Ø49 Tmin 1.5K Tmax 600K Instrument D2B Sensor Regul. (top) RhFe Serial number E457 Calibration ILL ...
Relevance: 19%
Pages
install gdebi Install the debian package: sudo gdebi rplot_1.4.0-1_amd64.deb Start the program by typing Rplot Recent updates (since v1.0) v1.8 (March 2025) 'Integrate visible detector area' has been improved ... and differences can now also be removed from the list by right-clicking them update 15/03/2024 (v1.7.1): possibility to load ubfrom.raf ...
Relevance: 18%
Pages
Tm Detector 32 x 32 pixels, each 1 cm 2 at a distance of 4.6 m from the sample 1 bar 3 He and 0.3 bar CF 4 area 32 x 32 cm 2 pixel size 1 cm 2 angular range θ 2° ... 70° (Cryostat) 2° ... 30° (Oven, Sample ... cavity, 1 m long (provided by HZB Berlin) FeCo-Si supermirrors on Si substrate analyser FeCo supermirrors (provided by HZB Berlin) ...
Relevance: 18%
Pages
verdazyl ring (carrying a spin 1/2) surrounded by three phenyl groups.This compound is described by linear S = 1/2 antiferromagnetic (AF) Heisenberg chains. Below TN = 1.78 K, due to small interchain ... the c-axis, in terms of group theory. This small AF moment (1 μB is expected for a spin 1/2) can be interpreted interms of spin reduction in S = ...
Relevance: 18%
Pages
energies, and wavevectors: 1.26 < λ/Å < 6.3 2.1 < Ei/meV < 42 1.0 < ki/Å-1 < 5.0 Measurements with a calibrated monitor at the sample position show for a typical wavevector of ki=2Å-1 a flux of about: double ... double focusing set up: 1.04 x 108 n cm -2 s -1 velocity selector in: 8.4 x 107 n cm -2 s -1 velocity selector, 60' collimation: 5.02 x 10 ...
Relevance: 18%
Pages
2017 ~ 1.5 - 8 energy transfer (μeV) ±31 ±31 ±59 t.b.d., ~ ± 250 / ±70 / -850...1000 for Si(111) / Si(111) high rep. rate / Si(311) Q-range (Å -1 ) 0.1 - 1.8 0.1 - 1.8 0.7 - 3.5 t.b.d. ~ 0.2 - 1.8 comments ... comments high flux (HF) standard position NEW: choose chopper ratio 1:1 for 'high flux' or 2:1 for 'high signal-to-noise' (HSNR-mode) low ...
Relevance: 18%
Pages
Calibration ILL #2007-9 Interpol. Table download (txt - 5.67 Ki) (svg - 1.31 Mi) (svg - 484 Ki) (svg - 1.31 Mi) (svg - 1.31 Mi) (svg - 1.31 Mi) (svg - 491 Ki) (svg - 499 Ki) (svg - 492 Ki) (svg - 496 Ki) (svg ... number X139472 Calibration ILL 2018-3 Interpol. Table download (txt - 5.68 Ki) (svg - 1.30 Mi) (svg - 1.31 Mi) (svg - 1.31 Mi) Superfluid ...
Relevance: 18%
Pages
Pinholes 0.5 to 2.9 mm Flux at specimen (λ-centre = 3.5 Å; δλ/λ = 30%) ~1.1 x 10 8 n cm -2 s -1 Detector Cylindrical drum with internal neutron-sensitive image plates and read/erase system Neutron image plate ... Guide hall n°1, cold guide H143 Data Collection Method Quasi-Laue Ni/Ti multilayer band-pass filter (δλ/λ=30%) Choice of neutron λ ranges ...
Relevance: 18%