MFC #1 flow-rate of N2 dry line (sccm) 28 Read Real MFC #2 flow-rate of N2 dry line (sccm) 30 Read Real MFC #3 flow-rate of H2O saturated line (sccm) 32 Read Real MFC #4 flow-rate of H2O saturated line (sccm) ... (sccm) 42 Read Real Temperature of H2O bath #1 (°C) 44 Read Real Temperature of H2O bath #2 (°C) 46 Read Real Temperature of D2O bath #3 ...
Search
Searched for %2.
Found 994 results in 4 milliseconds.
Displaying results 71 to 80 of 994.
Pages
Relevance: 18%
Pages
sensitive with 32 x 32 pixels Pixel size 2 x 2 mm 2 0.25° x 0.25° Sensitive area 64 x 64 mm 2 Sample-detector distance 40 cm Sample environment Displex cryostat with J-T stage 2 K Peltier cooler gas flow furnace ... neutron beam H3 Monochromators Cu (220) Take-off angle 2θM 13 - 56 ° Wavelength λ 0.25 - 0.85 Å Sample Beam size 0.6 x 0.6 cm2 ...
Relevance: 18%
Events - From 12.01.25 to 12.01.25
Relevance: 18%
Pages
: H 2 O/D 2 O mixture in mass: 100 mg of H 2 O + 150 mg of D 2 O. Mass fraction of H 2 O = 100/(100+150) = 0.4 Molar masses: 18 g/mol for H 2 O and 20 g/mol for D 2 O. Results: Mass fraction of D 2 O = ... angle: 10.12 degrees (for Q = 0.865924 Å -1 ) Calculator Lambda 1 = Å Lambda 2 = Å 2Theta 1 = deg 2Theta 2 = deg Q = Å -1 ...
Relevance: 18%
Pages
: H 2 O/D 2 O mixture in mass: 100 mg of H 2 O + 150 mg of D 2 O. Mass fraction of H 2 O = 100/(100+150) = 0.4 Molar masses: 18 g/mol for H 2 O and 20 g/mol for D 2 O. Results: Mass fraction of D 2 O = ... angle: 10.12 degrees (for Q = 0.865924 Å -1 ) Calculator Lambda 1 = Å Lambda 2 = Å 2Theta 1 = deg 2Theta 2 = deg Q = Å -1 ...
Relevance: 18%
Pages
angles HOPG (002) Cu (200) take-off angle 2θ λ/Å Φ/n s-1cm-2 λ/Å Φ/n s -1 cm -2 26° - - 0.82 2.4 x 10 7 28° - - 0.88 3.2 x 10 7 30° - - 0.94 4.3 x 10 7 42° 2.41 4.2 x 10 7 1.30 9.8 x 10 7 Germanium monochromator ... 63-122° hhl λ/2 contamination at λ = 1.3 Å about 0.3 % λ/2 at λ = 2.4 Å removed by graphite filters Collimation primary collimation α1 ...
Relevance: 18%
Pages
value1 to value2. e.g. SCAN OME 5 15 .17 (or SOM 5 15 .17) If value1 > value2 the routines will default to a centred stepped scan about value1 of width value2. ie scans from value1 - (value2/2) to value1 + ... + (value2/2) e.g. SCAN OME 10 2 .2 ( scan from 9 to 11 in Omega ) also SCAN PHI = 1 .1 ( scans .5 deg. either side of current angle.) If the ...
Relevance: 18%
Pages
indium 114.82 12d 1.1x10 4 9.5 † I iodine 126.904 7h 1.2x10 5 100 Ir iridium 192.2 4.2y 5.0x10 4 43 † Fe iron 55.847 - - - Kr krypton 83.80 42h 3200 2.8 † La lanthanum 138.91 22d 1.9x10 4 16 Pb lead 207.19 ... 92.906 80m 2.0x10 4 17 N nitrogen 14.007 - - - Os osmium 190.2 41d 2300 2.0 † O oxygen 15.999 - - - Pd palladium 106.4 9d 7. lx10 4 60 P ...
Relevance: 18%
Pages
orthorhombic structure in the alloy, Tb5Si2Ge2.Red balls: silicon or germanium atoms ; yellow balls: terbium atoms ; arrow marks: where a strong shear movement leads Fig. 2: The percentage of monoclinic phase ... Si 2 Ge 2 indicate that, as the temperature drops, a strong magnetic moment appears alongside a change in crystal structure from ...
Relevance: 18%
Pages
FoV: FoV [mm 2 ] Pixel size [μm] from 30 × 30 to 170 ×170 * from 15 to 83 High resolution detectors **: FoV [mm 2 ] Pixel size [μm] 42 × 42 21 32.5 × 32.5 16 14.6 × 14.6 7.1 8.6 × 8.6 4.2 7.3 × 7.3 3.6 ... meV / 2.8 Å Fastest tomography 1.5 s Wavelength Definition Wavelength resolution DCM Δλ/λ ̴ 5% Wavelength resolution VS Δλ/λ ̴ 16% Sample area ...
Relevance: 18%