operating temperatures between 2.2 K and about 150 K. Two-stage PTCs are available that supply cooling powers at 4.2 K ranging from 0.15 to 1.1 W with electrical input powers from 2 to 10 kW. Demonstrated a ... Spallation Accelerators as well), the company SDMS/SNLS provides specific UHV Chambers, customized LN2, LHe or LH2 Cryostats, Lines or ...
Search
Searched for %2.
Found 994 results in 4 milliseconds.
Displaying results 331 to 340 of 994.
Pages
Relevance: 16%
Pages
Off-specular scattering in 2θas recorded on D17 from lipid bilayers. Lipid bilayers and thermal fluctuations Lipid bilayers are increasingly used as ideal models of cell membranes. They are characterised ... one dimension giving rise to Bragg diffraction peaks. The figure shows the off-specular scattering in 2θ stemming from thermal fluctuations. ...
Relevance: 16%
Pages
A simulated experiment The incoming polychromatic neutron beam (wavelength around 2.2 Å) is backscattered on the monochromator (Bragg reflexion on a crystal lattice) with a high monochromaticity (energy
Relevance: 16%
Pages
For the Orange cryostats and the 2.5T vertical magnet 90ILHV42 Type Dilution insert Tmin 50mK Tmax 300K Instrument Pool Sensor Mix. Ch. Cernox CX1050 Serial number X48375 Calibration ILL 2007-10 Interpol ... CX1030 Serial number X47844 Calibration OIS Interpol. Table download (txt - 5.19 Ki) Sensor Mix. Ch. RuO2 1000 Serial number U02209 ...
Relevance: 16%
Pages
Table download (txt - 5.70 Ki) Sensor Still RuO2 Serial number N3-151102 Calibration LakeShore Interpol. Table download (txt - 5.70 Ki) Sensor Mix. Ch. RuO2 Serial number U09718 Calibration LakeShore #1352105
Relevance: 16%
Pages
For the Orange cryostats and the 2.5T vertical magnet 90ILHV42 Type Dilution insert Tmin 40mK Tmax 300K Instrument Pool Sensor Mix. Ch. Cernox CX1050 Serial number X47217 Calibration ILL 2007-5 Interpol ... Serial number X46855 Calibration LK #? Interpol. Table download (txt - 5.19 Ki) Sensor Mix. Ch. RuO2 Serial number U02205 Calibration LK #? ...
Relevance: 16%
Pages
ILL 2013-2 Interpol. Table Download (LK336) (txt - 5.65 Ki) Download (LK340) (txt - 5.64 Ki) 210ILEF49 SMP X87166 (pdf - 417 Ki) The sample placed between electrodes will be screwed with a M2/male of
Relevance: 16%
Pages
Long tail Stick #2 is compatible with the use of a sample rotation stage. Type Orange Ø70 Tmin 1.5K Tmax 320K Instrument IN16B Sensor Samp. #1 Cernox CX1050 Serial number X144617 Calibration ILL 2019-1 ... Serial number X48351 Calibration ILL 2007-9 Interpol. Table download (txt - 5.70 Ki) Sensor Samp. #2 Cernox CX1050 Serial number X98421 ...
Relevance: 16%
Pages
Calibration ILL 2007-2 Interpol. Table download (txt - 5.65 Ki) Sensor Samp. #1 Cernox CX1050 Serial number X76450 Calibration ILL 2012-1 Interpol. Table download (txt - 5.70 Ki) Sensor Samp. #2 Cernox CX1050
Relevance: 16%
FAQ - Reactor safety
trigger further fission events in order to sustain the chain reaction (thermal neutrons with a speed of 2.2 km/s) and to supply neutrons to the scientific instruments. Three components located in the immediate ... most intense continuous neutron flux in the world, namely 1.5 x 1015 neutrons per second and per cm2. Its thermal power of 58 MW ...
Relevance: 16%