workhorse instrument is its large “banana” 1D position-sensitive detector, operational since 2000; this detector consists of a curved pressure vessel – and hence its name - containing active elements called MSGC ... providing high local counting rate capability. More detailed information about MSGCs can be found in [1] a nd [2] . This technique was ...
Search
Searched for 2.1 - 1.5.
Found 365 results in 9 milliseconds.
Displaying results 281 to 290 of 365.
Pages
Relevance: 37%
Pages
controller to the Kepco ATE 100-2.5 power amplifier. With this electronics, the power amplifier is protected against abnormal LakeShore output voltages and delivers up to 2.5 times the power provided by a ... zones (e.g. zones 1 and 2 for Ø49 Orange Cryostat and zones 3 and 4 for Ø100 Orange Cryostats). The LakeShore determines the zone to apply ...
Relevance: 36%
Pages
graphical timeline below (pdf - 41 Mi) Beam tubes/guides renewal and construction works The most critical project during the past 14 months has been the replacement of the H1-H2 beam tube and in-pile neutron ... infrastructure such as the H1-H2 pool at level C, which provides biological shielding for beam extraction, and the guide system for ...
Relevance: 36%
Pages
of the participants Download 360p (mp4 - 17.05 Mi) File size: 17.1 MB Resolution : 640x360 540p (mp4 - 26 Mi) File size: 26.1 MB Resolution : 960x540 800p (mp4 - 38 Mi) File size: 56.3 MB Resolution : ... speakers Download 360p (mp4 - 18.96 Mi) File size: 23.5 MB Resolution : 640x360 540p (mp4 - 28 Mi) File size: 37.3 MB Resolution : 960x540 800p ...
Relevance: 36%
Pages
values are corrected by the zero angle, i.e. 2theta= 2theta_read - 0.5 prompt> d4creg -z 0.5 -w 0.495 -o sample.qreg 175568 175579 This command produces a diffractogramme as a function of Q. Data are corrected ... "outfile.reg1" (regrouped data of detector 1) "outfile.reg2" (regrouped data of detector 2) "outfile.reg3" (regrouped data of detector ...
Relevance: 36%
Pages
continuously load cells and VX-1 and VX-5 Paris-Edinburgh presses. Combined with the VX-5, it allows to regulate quickly and precisely the sample pressure up to 10 GPa at temperatures down to 3 K in our ... charge the device at up to 2 kbar of helium gas in 20 minutes, control ramps at 30 bar/min and maintain the pressure constant with variations ...
Relevance: 36%
Pages
: D1B , D2B , D20 , D3 , D4 , XTREMD SANS spectrometers: D11 , D22 , D33 Small momentum transfer diffractometer: D16 Triple-axis spectrometers: IN1 , IN8 Time-of-flight spectrometers: PANTHER , IN5 , SHARPER ... exhibit complex behaviours. Proper understanding of these systems require a multidisciplinary approach - combining neutron experiments and ...
Relevance: 36%
Pages
[UNDER CONSTRUCTION IN 2018] (jpg - 111 Ki) Dimensions: 5,5 L x 3,7 W x 4 H / Vacuum: 1 x 10-3 mbar Material: Aluminium AW-5083 (jpg - 40 Ki) Material: Aluminium AW-5083 (jpg - 54 Ki) Material: Aluminium AW-5083 ... comply with French regulations for all on-site and civil engineering work. This includes - Electrical certifications - The provisions ...
Relevance: 36%
Pages
r with variable resolution - Thermodiffractometry - Magnetism - Kinetics - Multi-stroboscopy - Texture - Very small samples - Highly absorbing samples - Disordered systems - Physisorption D4 Disordered ... diffractometer - Soft matter - Polymer, colloids, membranes and self assembly - Biological macromolecules in solution - Biophysics - Magnetism, ...
Relevance: 36%
Pages
M. Zbiri The team used two neutron spectroscopy techniques - quasi-elastic neutron scattering (QENS) and inelastic neutron scattering (INS) - to look at how the water, which could be seen as ‘a guest’ ... hydrogen to probe the response of the photocatalysts to the introduction of water. The use of D 2 O instead of H 2 O allows then to tune the ...
Relevance: 36%