Equipped with a new-generation cold-valve Type Orange Ø49 Tmin 1.8K Tmax 550K Instrument Pool Sensor Samp. #1 RhFe Serial number 9060 Calibration OI #10448 Interpol. Table Download (txt - 5.69 Ki) Sensor
Search
Searched for a.
Found 1524 results in 4 milliseconds.
Displaying results 271 to 280 of 1524.
Pages
Relevance: 17%
Pages
vacuum via the vacuum valve to better than 10 -5 using a turbo-pump. Be sure to use a flexible line that has NEVER been used for pumping helium. Connect the temperature controller to the regulation socket ... Procedure for preparing a wet cryostat or cryofurnace To simplify the operations, the cold valve will stay open during the whole procedure. ...
Relevance: 17%
Pages
with a maximum current of 400 mA and a maximum power of 12 W. The settings depend on the controller used: - LakeShore 336: Heater Resistance: 50 Ohms, Max Current: User, User Max Current: 0.400 A, Heater ... view of a high-pressure stick Schematic view of a high-pressure stick with insulated heated capillary for liquid pressure cells. The 700 MPa ...
Relevance: 17%
Pages
time that had been lost before deciding to constitute a sample environment group. J. Kalus works on the design of a cryostat for studying phonons as a function of temperature. 1971 the reactor's first divergence ... with a THOR cryostat. Contract signed with CNRS/CRTBT (May 73) for the construction of a dilution cryostat . Testing starts at the end ...
Relevance: 17%
Pages
the 1973 photo of D1B sporting a cryomagnet. This magnet doubtless produced a lowly magnetic field, using a traditional magnetic coil. Peter Suttling thinks it was probably a cryomagnet from Oxford Instruments ... getting the same level of field a second time round. ILL bought a 10-Tesla coil of this type in 1981 for D7. Peter Suttling also ...
Relevance: 17%
Pages
linked to the ILL intranet and SANE developed He4Ever , a pair of iPhone applications - the one, a mobile terminal for data entry, and the other a means of calculating the movement of helium. This gives ... 1972 to 2005 ILL used a 7 m 3 Zodiac-brand gas bag. In 2005 Marcello transferred the flexible gasometer from ILL 15 to the main stores. The bag ...
Relevance: 17%
Pages
Stirling W G, Scherm R, Hilton P A and Cowley R A 1976 J Phys C: Solid St. Phys. 9 1643-63. " The cryostat had a liquid nitrogen bath and a liquid 4He bath which was pumped down to a temperature of 2.5 K. Below ... Phys. Appl. 19 , 9 (1984). K.Neumaier, A.Heidemann, A.Magerl, Rev. Phys. Appl. 19 , 773 (1984) A. Benoît, S. Pujol, "Cryostat à ...
Relevance: 17%
Pages
developing and adopting a USI standard: a protocol that makes trans- parent the communication between equipments and electronics, analogous to the USB between peripherals and computers. A USI certified equipment ... necessary to reset a list of electronics. For example, it suffices to plug a cryostat to reset the temperature and cold-valve ...
Relevance: 17%
Pages
automatic recognition and combination of the equipments, etc. After a brief presentation of the progress already performed, we present a roadmap, the projects that are going to be financed and those requiring ... A sample environment roadmap for ILL future Eddy Lelièvre-Berna, Helmut Schober Institut Laue Langevin, 6 rue Jules Horowitz, 38042 ...
Relevance: 17%
Pages
allowed researchers to establish a universal theoretical description of cell membranes Red blood cells 3d illustration (Credits: AdobeStock) In every cell of our bodies, a myriad of chemical reactions takes ... step to obtain a detailed representation of the structures and processes studied. This step can often be tricky, especially in systems as ...
Relevance: 17%
