double focusing set up: 1.04 x 108 n cm -2 s -1 velocity selector in: 8.4 x 107 n cm -2 s -1 velocity selector, 60' collimation: 5.02 x 10 7 n cm -2 s -1 Due to the double curvature of the neutron guide there ... energies, and wavevectors: 1.26 < λ/Å < 6.3 2.1 < Ei/meV < 42 1.0 < ki/Å-1 < 5.0 Measurements with a calibrated monitor at the sample ...
Search
Searched for 2.1 - 1.5.
Found 363 results in 4 milliseconds.
Displaying results 11 to 20 of 363.
Pages
Relevance: 81%
Pages
transformation planning see page "The conversion to Unix" T he CARINE system at the ILL: IN1,IN2,IN3,IN8,D1A,D1B,D2,D4,D5,D6,D8,D9,D10 Engineers: Walther Kaiser (3-axis), Alain Barthelemy (Diffraction) Programmers: ... required: - Time-of-flight spectrometers: IN4, IN5 (inelastic, quasi-elastic scattering) - Diffuse scattering diffractometer: D7 - ...
Relevance: 78%
Pages
99.9% efficient, wavelength dependent) 0.002 Å-1 < q < 2 Å-1 Non-polarised monochromatic Ni/Ti multilayer stack Wavelength 5.5 Å 0.005 Å-1 < q < 1.5 Å-1 Resolution Δλ/λ = 4% (FWHM) Polarised monochromatic ... rate 0.75 MHz (measured in monochromatic mode with 5.6 Å neutrons) Translation 1.0-3.1 m Rotation -2 to +45 deg. Size 250x480 mm 2 Resolution ...
Relevance: 78%
Pages
CX1050 Serial number X144620 Calibration ILL 2019-1 Interpol. Table Download (txt -5.68 Ki) Sensor Magnet - Serial number - Calibration - Interpol. Table - IPS-120 Test 07 superconducting magnet parameters ... vertical symmetric Type ILL VTI Tmin 1.5K Tmax 300K Instrument D2B Sensor Regul. Cernox CX1020 Serial number X28899 Calibration LakeShore ...
Relevance: 78%
Pages
Electromagnet 0.22 - Ø49 Ø36 with dilution 40 mK - 320 K for SANS, reflectometry ±6.5° B // n ±6.5° B perp. n -- Narrow tail + GM Electromagnet 0.9 - Ø14 1.5 K - 320 K for SANS, reflectometry ±4.5° B // n ±15° ... ±15° B perp. n -- ORTF 2.5- Ø24 Ø18 with dilution 40 mK - 300 K for SANS, reflectometry ±15° B // n ±15° B perp. n -- 268HTCC81 3 - ...
Relevance: 78%
Pages
ILL 2009-1 Interpol. Table Download (txt -5.70 Ki) Sensor Samp. Cernox CX1050 Serial number X48399 Calibration ILL 2009-1 Interpol. Table Download (txt -5.70 Ki) Sensor Magnet - Serial number - Calibration ... Calibration - Interpol. Table - (svg - 287 Ki) (svg - 287 Ki) IPS-120 Test 07 superconducting magnet parameters (Test 06 magnet system ...
Relevance: 78%
Pages
90ILHV42 2.5 asymmetric 30 Ø42x130* Ø30 with dilution 40mK - 300K 85° pillar -5° to +5° vertical access Ø286 in scat. plane 1995 176ASHV49 (D2B) 6 40 Ø49 1.5- 300 -3 to +3° vertical access - 2006 156OXHV49 ... Ø35 with dilution 40mK - 300K -5° to +20° vertical access, very low temperature insert available Ø388 in scat. plane 1994 206OXHV26 7 ...
Relevance: 77%
Pages
wave-number (Å -1 ) 2.8, <1.5, 1.22.8, 1.5, 1.22, 1.5 4.15 4.1 Incident flux (n/cm 2 /s) 2.4*10 8 , 1.2*10 8 , 5*10 7 1.3*10 8 , 4*10 7 , 3*10 7 2.7*10 7 , 2*10 7 10 9 5*10 8 5*10 8 2.5*10 8 Energy resolution ... 06 0.4, 0.21.1 PG002 analyser, kf=2.662 Å -1 0.9 PG002 analyser, kf = 2.662 Å -1 0.55 (Cu200 analyser, kf = 2.662 Å-1) 1.0 PG002 ...
Relevance: 77%
Pages
63 (att 1), f a =16.9 (att 2), f a =72.7 (att 3) f a =77.7 (att 1 + 2), f a =348 (att 1 + 3), f a =1165 (att 2 + 3) f a ≈8200(att 1 + 2 + 3) Sample area flux at specimen at lowest resolution 1.2 · 10 8 ... distances 1.6, 3.1, 4.1, 5.6, 6.7, 7.7, 10.2, 12.7, 15.2, 16.5, 17.8, 20.3, 22.8, 24.8, 26.9, 29.4, 31.9, 35.2 m (18 discrete distances) 4 ...
Relevance: 77%
Pages
rate / Si(311) Q-range (Å -1 ) 0.1-1.8 0.1-1.8 0.7 - 3.5 t.b.d. ~ 0.2-1.8 comments high flux (HF) standard position NEW: choose chopper ratio 1:1 for 'high flux' or 2:1 for 'high signal-to-noise' ... wavelength (Å) 6.271 6.271 3.275 5.654 dlambda/lambda ~12% incident energy (meV) 2.08 2.08 7.63 2.56 flux at the sample (n/cm 2 /s) @ 58 MW HF: ...
Relevance: 76%
