(100 Å) : about 10 5 cm -2 s -1 (m/s) -1 (= 0.4 x 10 5 cm -2 s -1 Å -1 ) UCN (4 ports) beam sizes: 4 x 4, 7 x 7, 10 x 10 and 14 x 10 cm 2 total flux: 2.6 x 10 4 cm -2 s -1 for v z < 6.2 m/s (3.3 x 10 4 for ... = 40 m/s (100 Å) is about 10 5 cm -2 s -1 (m/s) -1 (= 0.4 x 10 5 cm -2 s -1 Å -1 ). The 4 UCN beams have cross sections as follows: 4 x 4, 7 ...
Search
Searched for 2.1 - 1.5.
Found 365 results in 3 milliseconds.
Displaying results 131 to 140 of 365.
Pages
Relevance: 44%
Pages
64 Go Power supply 5 V Case made in 3D printing by Yannick Raoul Fastening clamp Camera locations DRE1 ILL5 (08/04/2022 - ) Level C Above the H1/H2 swimming pool DRE2 ILL5 (18/02/2022 - 18/05/2022) Level ... reactor (18/05/2022 - ) Level C In front of IN8 - (test de renoyage ultime) DRE3 ILL5 (22/02/2022 - ) Level D Above the swimming pool of the ...
Relevance: 44%
Pages
cradles - LakeShore plugged to the displex Zone Top of the zone (K) Proportional (P) Integral (I) Derivative (D) Manual Ouput (%) Heater Range 1---- 0.00 -2---- 0.00 - 3 ---- 0.00 - 4 --- - 0 ... 0.00 -5---- 0.00 - 6 ---- 0.00 - LKC-340 Converter The LKC-340 electronics links the LakeShore Model 340 temperature controller to ...
Relevance: 44%
Pages
/Å -1 < 4.9 Q -resolution ΔQ/Å -1 < 0.1 Detectors monitors 2 35 3 He detectors 1 <Q/Å -1 < 4.9 3 He PSD detector 0.2 <Q/Å -1 < 0.8 background per detector 0.5- 4 cpm Sample environment furnace 300 < T ... ≥25°C) 2.23 Å energy resolution 8 µeV Deflector pyrolytic graphite with variable curvature Sample sample size 3.5 x 3.5 cm 2 flux at sample 4,4 ...
Relevance: 44%
Pages
Calibration method Tmin (K) Tmax (K) ∆T (K) Tmin (K) Tmax (K) ∆T (K) 1.40 2.00 0.10 29.0 50.0 3.0 2.00 6.00 0.20 50.0 105.0 5.0 6.00 29.00 1.00 105.0 325.0 10.0 The best accuracy is obtained by using the CX-1030 ... We perform calibration fits in the ranges 1.3 - 14K, 14 - 82K and 82 - 325K and produce a LakeShore 340 ASCII file containing 200 ...
Relevance: 44%
Pages
capillary and 2-wire measurement Type Stick for Orange Ø70 Tmin 1.5K Tmax 550K Instrument Pool Sensor Samp. RhFe Serial number E507 Calibration ILL #2014-1 Interpol. Table Download (LK336) (txt -5.37 Ki) Download ... Download (LK340) (txt -5.37 Ki)
Relevance: 44%
Pages
30x30 mm diameters: 5, 10, 20, 30 mm Sample area Maximum flux at sample (for Δλ/λ = 10%) 4.1x10 7 n cm -2 s -1 Brightness (flux / unit solid angle) 3.57x10 11 n cm -2 s -1 strd -1 Maximum sample dimensions ... Furnace, Stopped-flow, Shear cell Detectors Sample - Detector distances 1.2 ... 12.8 m Detector 1 (rear): Single panel monoblock 640 x 640 ...
Relevance: 44%
Pages
field (0 - 20 kV AC/DC) Type Stick for Orange Ø49 Tmin 1.5K Tmax 320K Instrument Pool Sensor Samp. Cernox CX1050 Serial number X98448 Calibration ILL 2015-1 Interpol. Table Download (LK340) (txt -5.64 Ki) ... Ki) Download (LK336) (txt -5.65 Ki) (pdf - 417 Ki) The sample placed between electrodes will be screwed with a M2/male of M6/femelle ...
Relevance: 44%
Pages
ILL 2007-2 Interpol. Table download (txt -5.67 Ki) Sensor Regul. #2 Cernox CX1050 Serial number X121474 Calibration ILL 2017-6 Interpol. Table download (txt -5.62 Ki) (svg - 281 Ki) (svg - 274 Ki) (svg ... Thin tail Type Orange Tmin 1.5K Tmax 320K Instrument Pool Sensor Regul. Cernox CX1050 Serial number X46954 Calibration ILL 2007-2 Interpol. ...
Relevance: 44%
Pages
ki (Å -1 ) flux (10 7 n.cm -2 s -1 ) Conditions polarised Heusler (111) (230x150mm 2 ) 3.437 2.662 4.1 8.0 1.05 7.0 0.55 virtual source D=40 mm sapphire filte unpolarised Si (111) (190x200mm 2 ) 3.135 ... filter wave-numbers k i = 2.66 Å -1 and 4.1 Å -1 are 0.82(3) meV and 3.05 (15) meV, respectively. Polarisation analysis can be performed in ...
Relevance: 44%