corrected in v 2.7 </project></name></name></name></name></name> Back to the D22 documentation Back to the LSS home page Find out more D22 Polarisation D22 Interlock D22 Manual D22 Short Manual D22 emergency ... emergency procedures D22 CommandFile D22NIH_Image lss phone numbers D22Computing D22pumping D22move_logicals D22cupboards D22_PF1_procedur ...
Search
Searched for D7.
Found 271 results in 4 milliseconds.
Displaying results 111 to 120 of 271.
Pages
Relevance: 14%
Pages
(22/02/2022 - ) Level D Above the swimming pool of the reactor, from the PF2 side DPT1 ILL7 (31/03/2022 - ) H15 Instrument zones of D11+/Sharp/SAM as seen from the Chartreuse side DPT2 ILL7 (04/04/2022 - ) H15 ... H15 From the walkway above the D17/IN5 zone DPT3 ILL7 (31/03/2022 - 01/09/2022) H24 Instrument zones as seen from the XtremeD side ILL22 ...
Relevance: 14%
Pages
either on D1B (fixed detector mode) or on D1A / D2B (scanning detector mode). Liquid & amorphous-type experiments (say D4 -type experiments). 1 - General Description You will find a schema of D20 in the ... similar to what is done routinely either on D1B (fixed detector mode) or on D1A / D2B (scanning detector mode). Liquid & amorphous-type ...
Relevance: 14%
Pages
w1=d17_waterdef('90230+90250',dims=1,mask='box,[190,200,63,222]') d17_waternorm function d17_waternorm,win,water LAMP function to normalize a workspace by the water file Designed to run with a 1D array ... LAMP interface d17_polcalc,[2206,10.2,20,2.1,2110,9.5,40,3.1],ferro=[1104,5.2,20,2.1,100,10.0,10,3.1],phi,F1,F2,p1,p2 d17_polcalc,'81624:81627' ...
Relevance: 14%
Pages
λ/Å Φ/n s-1cm-2 λ/Å Φ/n s -1 cm -2 26° - - 0.82 2.4 x 10 7 28° - - 0.88 3.2 x 10 7 30° - - 0.94 4.3 x 10 7 42° 2.41 4.2 x 10 7 1.30 9.8 x 10 7 Germanium monochromator for higher take-off angles Ge(113) ... reflections are also accessible, as listed in the table. The resolution approaches Δd/d = 10 -3 with a flux of the order of 10 7 n s -1 at the ...
Relevance: 14%
Pages
saturated line (sccm) 34 Read Real MFC #5 flow-rate of D2O saturated line (sccm) 36 Read Real MFC #6 flow-rate of D2O saturated line (sccm) 38 Read Real MFC #7 flow-rate of optional line (sccm) 40 Read Real MFC ... (°C) 44 Read Real Temperature of H2O bath #2 (°C) 46 Read Real Temperature of D2O bath #3 (°C) 48 Read Real Temperature of D2O bath #4 ...
Relevance: 14%
Pages
(with variable horizontal curvature; 12.2 x 11.8 cm 2 ) for polarization analysis: Heusler (111) (d = 3.44 Å; 7.5 x 14.5 cm 2 ) Double focusing set up horizontal divergence at sample position: 2-3o; Collimation ... guide dimensions 45 x 105 mm2 with tapering towards guide end: 20 x 140 mm 2 Monochromator PG (002); d = 3.355 Å height x width: 20 x ...
Relevance: 14%
Pages
individual partners at a time resolution of some seconds. Instrument: D22, small-angle scattering diffractrometer Re.: Scientific Reports 7, Article number: 40948 (2017) doi:10.1038/srep40948 Contact: Dr F ... combining time-resolved small angle neutron scattering (TR-SANS) with online-fluorescence spectroscopy on D22 in order to monitor the PAN ...
Relevance: 13%
Pages
instrument responsible on D11 Main areas of expertise : E-mail prevost(at)ill.eu Location SB336 - Science Building - 3rd floor Phone Phone : +33 (0)4 76 20 79 43 Mobile +33 (0)7 82 18 97 73 Instr. phone ... pieces of software will be an important part of the PhD work. Colloidal complexes between polyelectrolytes and oppositely charged nanoparticles ...
Relevance: 13%
Pages
et Systèmes, France) were acquired for D1B, IN1, IN2, IN3 etc. While the hardware outperformed the PDP11/34 systems chosen for the NICOLE instruments, IN4, IN4, D7, and PN1, the poor software support and ... shared systems for Time of Flight (CASSANDRA) and 4-circle instruments (ANDROMACHIE brought to ILL for D15/D16). The Pluto triple axis hence ...