position of D33 allows high magnetic fields and bulky environments at the sample position. Ref.: "The small-angle neutron scattering instrument D33 at the Institut Laue–Langevin", Dewhurst C.D., Grillo I ... distances (m) 2.8, 5.3, 7.8, 10.3, 12.8 Source apertures 30x50 mm (off-centre), 30x30 mm diameters: 5, 10, 20, 30 mm Sample area Maximum flux ...
Search
Searched for D7.
Found 271 results in 5 milliseconds.
Displaying results 101 to 110 of 271.
Pages
Relevance: 14%
Pages
2013 un événement significatif pour la radioprotection relatif à la présence d’un faisceau de rayonnements ionisants issu d’un dispositif expérimental, en dehors du bâtiment réacteur, dans une zone non ... dosimètre opérationnel de la présence d’un débit de dose significatif. Les investigations du service de radioprotection ont permis de déterminer ...
Relevance: 14%
Pages
CAMAC electronics shared across two Telemecanique T2000 systems CARINE , (IN1, IN2, IN3, D1A, D1B, D2, D4, D5, D6, D8). A single program was active at any one time, others being swapped out to disk. Each ... arrays, event data were transferred from CAMAC to a Telefunken TR86 system NICOLE . This served D11, D7, IN4, IN5, and PN1. Each instrument ...
Relevance: 14%
Pages
detector assembly is a array of nine 1D position sensitive detectors with an angular resolution of 0.125º. The available 2θ-range is 1.5º to 140º. Because there are 7º in between two detectors, 2-positions
Relevance: 14%
Pages
D20 - High-intensity two-axis diffractometer with variable resolution D20 is very high intensity 2-axis diffractometer equipped with a large microstrip detector. Due to the extremely high neutron flux ... over the complete diffraction pattern at the highest take-off angle with a neutron flux of up to 10 7 ns -1 cm -2 or a high flux of up to 10 8 ns ...
Relevance: 14%
Pages
A rocking curve from a membrane multilayer recorded with the 256 x 256 mm2 detector. D16Watch the successive peaks which appear while the sample is rotated. Here the sample is a crystallized dilute lamellar ... detector positions. Typical patterns with the classical detector Until 2009, the neutron detector of D16 was a 3 He bidimensionnal detector ...
Relevance: 14%
Pages
Type Orange Thin-Tail Tmin 1.5K Tmax 320K Instrument D3 Sensor Regul. Cernox CX1050 Serial number X48303 Calibration ILL 2007-7 Interpol. Table download (txt - 5.70 Ki) Sensor Samp. Cernox CX1050 Serial
Relevance: 14%
Pages
Instrument 3D layout A cut of IN5B in a vertical plane along the beam axis (1) Main access gate (2) Choppers radiological protection (3) Monochromator choppers (4) Frame overlap and contaminant order choppers ... choppers (5) Focusing guide (6) Sample environment lift (7) Sample chamber (8) Position sensitive detectors (9) Background shielding (10) ...
Relevance: 14%
Pages
NO Average M.W: 754.5 Fatty acid profile : Mol % dPG 14:0C 6,106461 16:0C 45,72489 cyclo17:0C 25,84755 16:1C 4,103299 16:2C 1,238905 18:0C 0,983789 18:1C 7,080874 cyclo19:0C 8,914234 CHROMATOGRAMS/SPECTRA
Relevance: 14%
Pages
2000°C Monochromators take-off angle 7° < 2θM < 38° wavelength 0.42 Å < λ < 0.843 Å polarising, high-flux, low resolution Heusler Cu 2 MnAl (111) d = 3.362 Å 1x10 7 n.cm -2 .s -1 polarising, less-flux, ... better resolution Co 0.92 Fe 0.08 (200) d = 1.771 Å 2x10 6 n.cm -2 .s -1 non-polarised, high flux, high resolution Cu (200) d = 1.807 Å 1x10 ...
Relevance: 14%
