dtype= float32 ; shape= 6 B values cell dict Unit cell. It must be a dictionary of type cell_g_type or cell_gls_type . It can be generated with the function set_crystal_cell . r tuple The tuple returned by
Search
Searched for cell.
Found 372 results in 2 milliseconds.
Displaying results 91 to 100 of 372.
Pages
Relevance: 54%
Pages
dtype= float32 ; shape= 6 B values cell dict Unit cell. It must be a dictionary of type cell_g_type or cell_gls_type . It can be generated with the function set_crystal_cell . r tuple The tuple returned by
Relevance: 54%
Pages
High-pressure cells We propose different types of cells optimised to different instrument geometries and needs. A detailed list is provided on this page . 250, 600 and 700 MPa TiZr cells for investigating ... investigating flat samples, 0.5, 2 and 5 kbar cells with sapphire windows for SANS, 7 kbar cell with dielectric in-situ measurement. ...
Relevance: 54%
Pages
before and after the spin filter cell, respectively M1 and M2. The polarisation efficiency is defined by the equation below where M10 and M20 are measured for the cell depolarised while M1 and M2 are measured ... length of the cell in cm, T is the temperature in Kelvin, lbda is the neutron wavelength in Å, Pin is the incident polarisation and Aout ...
Relevance: 54%
Pages
are the primary component of cell membranes, and lipid monolayers on the surface of water can serve as a simplified model system of real cell membranes. As cancerous cells are known to have more charged ... drugs and cell membranes can be revealed by characterisation techniques such as neutron reflectometry, Brewster angle microscopy and the ...
Relevance: 54%
Pages
enter a setpoint of 0 and close the valve. Plug the capillary into the high-pressure cell or press, open the "Sample Cell" valve. Procedure for using the controller With the arrow keys of the Eurotherm controller ... when the temperature is high enough to truly release the pressure in the cell. If the temperature is too low, you must warm up the ce ...
Relevance: 54%
Pages
‘Each component within the electrolysis cell can be identified distinctly in the neutron images.’ CO₂ electrolyser cells in a nutshell A CO 2 electrolyser is a cell designed for the electrochemical reduction ... membranes, depending on the type of cell. Anion-exchange membranes (AEM) transport anions (such as hydroxide, OH - ) from the cathode to ...
Relevance: 54%
Pages
field magnets High Electric Field Sample sticks High Pressure Clamped cells Gas pressure cells Liquid pressure cells Paris-Edimburgh cells Sample sticks TiZr null-matrix alloy 4He melting curve Polarimetry
Relevance: 54%
Pages
Lambda = 1/2.d[hkl] in Å-1 for the reflection [h, k, l] of a cubic system. a is the length of the cell edges in Å. The expression is extracted from the International Tables for Crystallography (Vol. C): ... 1/2.d[hkl] in Å-1 for the reflection [h, k, l] of a hexagonal system. a and c are the lengths of the cell edges in Å. The expression is ...
Relevance: 53%
Pages
though the cell to be approximately 1/2 that of the fly-past beam around the sides of the cell. Interestingly, the radiographic image even shows attenuation contrast due to the quartz cylindrical cell walls ... group will deliver a polarised cell, pressurised as specified by the local contactor users. The gas pressure determines the cell opacity, ...
Relevance: 53%
