a fission fragment spectrometer based on a gas filled magnetic (GFM) device. PF1B Polarised cold neutron beam facility PF1B is dedicated to the particle and nuclear physics experiments. It provides the ... Scattering ( SANS ) l ets you to explore the microstructures of liquids and solids in scale ranging from 1 nanometre to one tenth of a micron. ...
Recherche
Recherche de 1'".
1023 résultats ont été trouvés en 3 millisecondes.
Affiche les résultats de 1 à 10 sur 1023.
Pages
Pertinence: 13%
Pages
The 1 GPa Gas Pressure Regulators supply continuously-loaded high-pressure cells with helium up to 1 GPa (10 kbar). Each system, built by SITEC , consists of a pneumatic-driven 2-head diaphragm compressor ... and the sample with helium up to 200 MPa, and a primary pump driving the pressure intensifier up to 1 GPa. The control loops and the ...
Pertinence: 100%
Pages
The 1 GPa Liquid Pressure Regulators supply continuously loaded high-pressure cells with a mixture of Glycerol/H2O up to 1 GPa (10 kbar). The pressure transmitting media is chosen according to the situation
Pertinence: 100%
Pages
s durables. Soutenu par la Région Auvergne-Rhône-Alpes et l’Union européenne, ce projet représente 1,8 M€ d’investissement dans le cadre du CPER EPN 2030 (Contrat Plan État-Région). Il contribue directement ... principales installations scientifiques du campus EPN à Grenoble. À elle seule, l’opération représente 1,8 million d’euros investis dans la ...
Pertinence: 100%
Pages
Buffer bottles Buffer valves Pumps (pdf - 5.26 Mi) Mixing valve Ante and Post 2-way valves (pdf - 1.40 Mi) Injector (pdf - 2.26 Mi) Column(s): HiTrap (pdf - 218 Ki) , Superdex75 (pdf - 268 Ki) , Superdex200 ... Sample requirements: as for cuvette measurement, the minimum sample requirement is about 200uL at 1-2mg/mL (after dilution by the ...
Pertinence: 100%
Pages
variations around the set point of less than 0.2 bar. It is used with continuously load cells and VX-1 and VX-5 Paris-Edinburgh presses. Combined with the VX-5, it allows to regulate quickly and precisely
Pertinence: 10%
Pages
cryostat that avoids the influence of gravity by using a capillary dilution chamber was developed [1,2] for experiments below 2 K. This system, where the sample was cooled down to 110 mK by a gravity- ... providing four-circle diffraction accessibility has been developed and commissioned successfully on D10. [1] A. Benoît and S. Pujol, Physica B ...
Pertinence: 14%
Pages
Type 10K Cryocooler Tmin 1.5K Tmax 320K Instrument D23 Sensor Regul. Cernox CX1050 Serial number X47423 Calibration ILL 2007-6 Interpol. Table download (txt - 5.70 Ki) (svg - 282 Ki)
Pertinence: 14%
Pages
agreement with the 1/v dependency of the absorption cross-section. (mp4 - 10.59 Mi) ©1996, E. Lelièvre-Berna, Institut Laue-Langevin, Grenoble, France. Movie files (940x360 pixels, duration: 1'40"): .mp4 (mp4 ... Videos AF Home AF D3: 1st experiment at the ILL with a 3 H e neutron spin filter (nov. 1996) Francis Tasset, leader of the 3 He project ...
Pertinence: 100%
Pages
rotation near the same p-wave resonance of 139 La and confirmed the prediction of the theory [1]. Reference 1- W. Heil at al. (1999) Physica B: Condensed Matter, 267–268 , 289-293. DOI: 10.1016/S0921-45 ... the text COW before TYREX A very first test of a 3 He filter was performed at the ILL on D3 in 1990 [1] using the spin-exchange optical pumping ...
Pertinence: 100%
