249 Cf, 251 Cf flux at target position 5.3 · 10 14 n cm -2 s -1 horizontal aperture 2β ≤ 2.3° vertical aperture 2α ≤ 0.57° solid angle W ≤ 3.2 10 -5 sr total length of main path 23 m length of exit slit ... cm energy dispersion for 1 % energy difference 7.2 cm mass resolution A/dA (FWHM) 400 for target size 0.8 x 7.5 cm 2 1500 for target size 0.16 ...
Recherche
Recherche de %2.
969 résultats ont été trouvés en 6 millisecondes.
Affiche les résultats de 71 à 80 sur 969.
Pages
Pertinence: 17%
Pages
Å) : about 10 5 cm -2 s -1 (m/s) -1 (= 0.4 x 10 5 cm -2 s -1 Å -1 ) UCN (4 ports) beam sizes: 4 x 4, 7 x 7, 10 x 10 and 14 x 10 cm 2 total flux: 2.6 x 10 4 cm -2 s -1 for v z < 6.2 m/s (3.3 x 10 4 for ... the figure. The total flux is 2.6 x 10 4 cm -2 s -1 for v z < 6.2 m/s (3.3 x 10 4 for v z < 7 m/s) resulting in calculated values for the density ...
Pertinence: 17%
Pages
Phone on the instrument: +33(0)4 76 20 7644 First Responsible JENKE Tobias Co-Responsible(s) FILTER Hanno Technician(s) BRENNER Thomas Click on name to obtain contact information.
Pertinence: 9%
Pages
D2B - High-resolution two-axis diffractometer D2B is very high-resolution powder diffractometer designed to achieve the ultimate resolution, limited only by powder particle size (Δd/d 5x10 -4 ), but is ... temperature/pressure/magnetic field structural (or magnetic) studies for powders Instrument layout D2B seen from behind the detector, i.e. from ...
Pertinence: 26%
Pages
A complete diffraction pattern is obtained after about 100 steps of 0.025° in 2θ, since the 64 detectors are spaced at 2.5° intervals. Such scans take typically 30 minutes; they are repeated to improve ... A general view The diffractometer D2B is characterised by the very high take-off angle (135°) for the monochromator, which has a relatively ...
Pertinence: 16%
Pages
Un-polarized equivalent flux at guide exit 2·10 10 n/cm 2 /s Polarized beam cross-section 3 cm by 4.5 cm or 6 cm by 8 cm Polarized equivalent flux 3·10 9 n/cm 2 /s Polarizers Curved stack of glass plates ... Guide hall n1 (ILL7), cold neutron guide H113 Vertical liquid deuterium cold source super-mirror (m=2) ballistic neutron guide H113, 76 m ...
Pertinence: 17%
Pages
Automated sample changer©2009, ILL, E. Suard & L. Gendrin The sample changer of D2B The automated sample changer makes it possible to measure several samples without human action. This can accomodate sample
Pertinence: 83%
Pages
France "Particle Physics with Slow Neutrons", October 22-24, 1998, Grenoble, France GRANIT-2014, March 2-7, 2014, Les Houches, France GRANIT-2010, February 14-19, 2010, Les Houches, France GRANIT-2006, April ... Cahen, S., Herold, C., Ghanbaja, J., Zhernenkov, K., Dubois, M. (2024). "Poly(dicarbon monofluoride) (C2F)n bridges the neutron ...
Pertinence: 10%
Pages
The set-up used for magnetic studies Here D2B is shown with a 5 Tesla cryomagnet installed on the sample table.
Pertinence: 14%
Pages
about 10 7 n/cm 2 /s Wavelength range 0.8 - 3.2 Å Sample stage-to-beam distance 40 - 70 mm Detector (1) (1) Photonics Science Limited, Robertsbridge, East Sussex, TN32 3LA, United Kingdom. 2 CCD cameras High ... type ND blue, based upon 6 Li with added ZnS:Ag Thickness: 0.45 mm Total active area: 252 x 198 mm 2 Each pixel is 144 µm on edge Distance ...
Pertinence: 16%