ve detectors, with a cell spacing of 2.5 mm. The distance between sample and detection surface is 1146 mm, giving an angular spacing of 0.125º per cell. Each detector of 64 cells covers therefore 8º in ... typically cylindrical Geometry 20 mm diameter by 50 mm height (max. values) Microstrips detectors 9 x 64 cells under 15 bar of 3 He detectors ...
Recherche
Recherche de cell.
429 résultats ont été trouvés en 5 millisecondes.
Affiche les résultats de 61 à 70 sur 429.
Pages
Pertinence: 42%
Pages
cryofurnace 1.5 to 525 K furnace 200 to1000 K cryomagnet dilution cryostat 50 to 4000 mK pressure cell 2 GPa and 4 to 300 K cryocooler 3.5 to 700 K Instrument description The diffractometer D2B is cha
Pertinence: 28%
Pages
trajectories, FIGARO is less well suited for the study of relatively small solid/liquid interface cells (i.e. 5 cm or less). A particularly useful feature of FIGARO, however, is the ability to gain flux
Pertinence: 22%
Pages
can supply upon request: standard dilution or He3 fridges, furnaces, pressure cells (gas cells up to 5 kbar, clamped cells up to 30 kbar), vertical field cryomagnets 6 and 15 T, horizontal field cryomagnet ... neutrons, in the incident wavelength range 1 - 3 Å. It can support large sample environments (pressure cells, up to 30 kbar, high field ...
Pertinence: 43%
Pages
selector bunker, and a radio-frequency spin flipper close to the sample zone. Tests with a 3He polariser cell have been perform to allow for polarisation anlysis. For details, see here. Sample position The sample
Pertinence: 20%
Pages
sample/n cm -2 s -1 0.4 x 10 6 max beam size 5 x 2 cm 2 Detector 3 He multidetector containing 1280 cells angular range 2θ 128° radius of curvature 1.500 m detector efficiency 86 % at λ = 2.52 Å max diameter ... programs are also available. The raw data are on-line corrected for efficiencies of the detector cells. In addition another Linux ...
Pertinence: 34%
Pages
environments such as an automatic temperature controlled sample changer, cryostat, magnet, shearing cell, Bohlin rheometer, dilution refrigerator, horizontal sample-changer under vacuum, etc. Neutrons scattered
Pertinence: 17%
Pages
du berceau d'Euler, il était donc monté sur un plateau tanzboden dont la rotation était asservie à celle de la rotation ω du 4-cercles. Ce dispositif délicat d'emploi était néanmoins une grosse avancée car ... flexions par des rotations, bien plus fiables et simples et qui, en outre, éliminaient les angles morts. Cela résulte d'une discussion ...
Pertinence: 39%
Pages
This compact cell is made from a hardened beryllium-copper alloy. It has a Ø5 x 20 mm sample volume. It uses Fluorinert as the pressure medium. The pressure is generated using a hydraulic press, then locked
Pertinence: 100%
Pages
High-Pressure Clamped Cells The ILL high-pressure clamped cells allow neutron scattering and spectroscopy experiments at pressures up to 30 kbar. Temperatures from 40 mK to 320 K, with single crystal, ... powder or liquid samples can be achieved depending on the cell. Clamped cells are loaded to the desired pressure in a press and then clamped ...
Pertinence: 100%