facility." Adv. High En. Phys. 2015: 730437. P. Crivelli, V.V. Nesvizhevsky, A.Yu. Voronin (2015). "Can we observe the gravitational quantum states of positronium?" Adv. High En. Phys. 2015: 173572. G. Dufour
Recherche
Recherche de cane.
660 résultats ont été trouvés en 4 millisecondes.
Affiche les résultats de 61 à 70 sur 660.
Pages
Pertinence: 1%
Pages
2.4 Å and 6 Å. Wavelengths can easily be changed under computer control, since they are all obtained by a simple rotation within the Ge[hhl] plane. A large graphite filter can be switched in to provide ... provide a very clean beam at 2.4 Å, and a cold Be-filter can be used for longer wavelengths.
Pertinence: 16%
Pages
detector can be changed between 10’ and ˝open˝. The sample table can support the mounting of high-field cryomagnets (up to 12T and 15T, respectively in the polarised and unpolarised modes). IN22 can be operated ... or polarised mode. Vertical guide fields are permanently installed. The incident/final polarisation can be continuously selected in the ...
Pertinence: 17%
Pages
long-duration (total duration of 100 ms, with a rise time of 23 ms) and high duty cycle (40-T shots can be repeated every 10 min). The diffraction experiment are carried out on the triple-axis spectrometer
Pertinence: 8%
Pages
i = 2.66 Å -1 and 4.1 Å -1 are 0.82(3) meV and 3.05 (15) meV, respectively. Polarisation analysis can be performed in combination with the standard ILL 2.5 T and 6 T vertical-field and 4 T horizontal-field ... Gauss), which automatically follows the direction changes of the scattering vector. This coil set can receive the standard ILL cryostats and ...
Pertinence: 14%
Pages
lifting detector. The neutron beam is polarised vertically. Large portions of the reciprocal space can be explored due to the relatively short wavelengths.
Pertinence: 16%
Pages
drive and PST lower background through background chopper and vacuum housing secondary spectrometer can be operated alternatively without vacuum several Doppler velocity profiles (sine, constant velocity)
Pertinence: 9%
Pages
Collimation Gadolinium coated Soller collimators with divergences of 10', 20', 30', 40', 60', 80' can be placed before sample, analyser, and detector 3He detector vertically mounted 12 cm high, 5 cm Ø ... and a Heusler (111) for polarization analysis. For use with polarized neutrons a supermirror bender can be mounted after the first collimator to ...
Pertinence: 16%
Pages
associated with each Cr 3+ ion is only 2.48 μB rather than the predicted 2.97 μB. The loss of moment can be attributed to covalent mixing of the Cr 3d electrons with O 2p orbitals in π-type antibonding orbitals
Pertinence: 13%
Pages
First test of an 3He neutron spin filter The nuclei of a helium-3 gas (3He) can be polarised. Thanks to the strong spin-dependancy of the neutron absorption a bottle filled up with that polarised gas would
Pertinence: 13%
