Guide hall n°1, thermal guide H22 Monochromator take-off angle 44.22° crystal pyrolytic graphite (002) wavelength 2.52 Å flux at sample/n cm -2 s -1 7.9 x 10 6 crystal Germanium (311) wavelength 1.28 Å flux ... the sample position provide a flux of 7.9·10 6 n cm -2 s -1 . A second wavelength with = 1.28 Å is available by using a germanium ...
Recherche
Recherche de 1'".
1022 résultats ont été trouvés en 3 millisecondes.
Affiche les résultats de 61 à 70 sur 1022.
Pages
Pertinence: 18%
Pages
analyzer (-> no contrast) with spin flipper, horizontal analyzer with spin flipper, varying analyzer Movie 1 - Neutron interferometry with polarized neutrons Without phase shifter (-> no contrast) A neutron i
Pertinence: 16%
Pages
Guide hall 1, thermal guide H22 Monochromators type Si-double focusing monochromator (from 1.5 to 2A), Cu-focusing monochromator (from 2-3A) dimensions 209 x 170 x 12 mm 3 wavelength range 1.3 - 3 Å variable ... 380 mm, 420 mm oscillation ± 1° Detector type 2-dimensional Position Sensitive microstrip Detector active area 25 x 25 cm 2 readout 256 x ...
Pertinence: 17%
Pages
to fragment. That leads to surface corrosion and reduces the battery lifetime. Experiments made on D1B followed changes during cycling on different electrode materials. These experiments showed that a ... intermediate γ phase with a cell volume between that of the α and β phases may appear (see figure 1) for some peculiar alloy compositions. The ...
Pertinence: 14%
Pages
of orientations of these coarse granules in samples of subduction rock (amphiboles), performed on D1B in 2002 by Michele Zucali. Ref.: Zucali M. , Chateigner D. , Dugnani M. , Lutterotti L. , Ouladdiaf
Pertinence: 12%
Pages
Why can’t alkaline batteries be recharged? D1B is a high intensity powder diffractometer with an 80° PSD (position sensitive detector). One of its major use is for kinetic and real time experiments like
Pertinence: 11%
Pages
the magnetic structures of MnRhAs The magnetic phase transition in MnRhAs have been investigated on D1B by recording the thermal evolution of the powder diffraction pattern over the whole 80° angular range
Pertinence: 13%
Pages
Reactor hall, through-tube H6-H7 Neutron Flux: 5 x 10 14 n cm -2 s -1 Available Crystals: Flat Si (220) Ge (111) Ge (220) Bent Si (220) Ge (220) Eff. Solid Angle: Flat: ~ 10-11 sr Bent: ~ 10-7 sr Best
Pertinence: 11%
Pages
10 14 n cm -2 s -1 horizontal aperture 2β ≤ 2.3° vertical aperture 2α ≤ 0.57° solid angle W ≤ 3.2 10 -5 sr total length of main path 23 m length of exit slit 72 cm mass dispersion for 1 % mass difference ... radius of deflection 0.6 m length of parabola to be focussed 40 cm distance magnet- focus 1.05 m size of image < 1 x 6 cm 2 Ionization chamber ...
Pertinence: 17%
Pages
More about D1B D1B Two-Axis Powder Diffractometer CRG-A Instrument (CNRS - CSIC/MCYT) French CRG site French Responsibles : Vivian Nassif Tel : +33 (0) 4 76 20 74 53 Laetitia Laversenne Tel : +33 (0) 4 ... describes the principal points to run easily the acquisition programs on D1B NOMAD is the data acquisition program used on ILL instruments. D1B ...
Pertinence: 18%