for lambda (lam): PG002: 0.988, Ang PG004: 1.977 Ang, Cu111=1.28 Ang. Sample-detector distances (dst) allowed on BRISP range between 2 and 6 m. w52=total(w2,3)*(1-w60); Possibility of looking at 2D (time ... are below listed: w1=rdrun(24420) Short measure of direct beam (numor 24420 in the example) made by removing the beam stop and inserting an ...
Recherche
Recherche de 1'".
1022 résultats ont été trouvés en 2 millisecondes.
Affiche les résultats de 51 à 60 sur 1022.
Pages
Pertinence: 17%
Pages
Guide hall 1, End of the thermal neutron guide H24 Diffraction geometry Transmission or backscattering Neutron beam Flux at sample position about 10 8 n/cm 2 /s Wavelength range 0.8 - 3.2 Å 10 detectors ... positioning Sample environment Standard ILL cryofurnaces 2.5 Tesla cryomagnet Standard ILL furnaces (1) Photonics Science Limited, ...
Pertinence: 14%
Pages
. 6 ns (7 Å) 0.6 ps ...0.6 ns (3.2 Å) Momentum transfer range 0.05 ... 1.1 Å -1 (10 Å) 0.07 ... 1.6 Å -1 (7 Å) 0.15 ... 3.6 Å -1 (3.2 Å) Instrument description Neutron spin-echo spectroscopy measures the
Pertinence: 16%
Pages
D1B (CRG) High intensity two-axis powder diffractometer D1B is a high intensity powder diffractometer with a PSD covering the angular range 0.8 to 128.8º. Highly demand for real time experiments, and for ... via solid-gas reaction Texture analysis Physisorption Instrument layout This layout shows the new D1B setup with the new Position Sensitive ...
Pertinence: 35%
Pages
example IN15 which can use 24 Å neutrons (wavelength twice the one of IN11) can reach resolution around 1 neV (240 kHz). In addition it has two options: a TOF mode of operation and a focusing mirror. IN11 is
Pertinence: 12%
Pages
30 (Ei= 8 meV) With standard focusing conditions the momentum resolution δ|Q| is about δ|Q| ≈ 0.02 Å-1. If needed, δ|Q| can be considerably enhanced by beam collimation with compromises in neutron flux.
Pertinence: 9%
Pages
polarized) 6×10 5 n s -1 cm -2 6×10 6 n s -1 cm -2 (expected value) flux (polarized) 3.2×10 5 orientation horizontal scattering plane Sample environment magnetic field up to 1.1T (optional 7T cryomagnet) ... detector distance to sample (variable) 1.1 - 6 m background (beam closed) 5 cts per minute 2 dim. position sensitive 3 He detector distance to ...
Pertinence: 18%
Pages
A general view The photos show D1B equipped with the new detector (2011) with 1280 cells and covering 128º in 2θ. Here the instrument is shown with no sample environment setup.
Pertinence: 14%
Pages
shown here equiped with the old PSD covering only 128º in 2θ. A cryostat 1.5-300K or even a dilution cryostat can be mounted on the D1B diffractometer enabling to investigate magnetic structures on powder
Pertinence: 16%
Pages
[220] skew symmetric interferometer at 1.84 Å with beam area 1x1 cm 2 flux in front of interferometer 16000 n cm -2 s -1 flux in O-bean and H-beam 7000 n cm -2 s -1 contrast in O-beam 90% wavelength spread ... reflection with tail suppression peak intensity 10000 n cm -2 s -1 angular resolution 0.01 sec arc momentum resolution 1.5 · 10 -5 Å -1 ...
Pertinence: 18%
