Sample environments Sample changer, Electromagnet, Cryostat, Cryomagnet, Furnace, Stopped-flow, Shear cell Detectors Sample - Detector distances 1.2 ... 12.8 m Detector 1 (rear): Single panel monoblock 640
Recherche
Recherche de cell.
417 résultats ont été trouvés en 7 millisecondes.
Affiche les résultats de 41 à 50 sur 417.
Pages
Pertinence: 28%
Pages
can supply upon request: standard dilution or He3 fridges, furnaces, pressure cells (gas cells up to 5 kbar, clamped cells up to 30 kbar), vertical field cryomagnets 6 and 15 T, horizontal field cryomagnet ... neutrons, in the incident wavelength range 1 - 3 Å. It can support large sample environments (pressure cells, up to 30 kbar, high field ...
Pertinence: 45%
Pages
selector bunker, and a radio-frequency spin flipper close to the sample zone. Tests with a 3He polariser cell have been perform to allow for polarisation anlysis. For details, see here. Sample position The sample
Pertinence: 21%
Pages
Robot A robot arm for manipulating radioactive (and other) samples 5. Experiments 5.1. Proliferating Cell Nuclear Antigen (PCNA) P. Schurtenberger et al. (1998) J. Mol. Biol. 275, 123-132 5.2. The diffusion
Pertinence: 20%
Pages
anodes per detection cell). The detection plates have each 32 cells of 2.568 mm (0.1˚) each, covering in total 3.2˚. The current PSD covers 153.6˚, as 48 plates were mounted. Each cell of one plate has an ... Each cell is connected to an amplifier, followed by an anti-coincidence logic (CLET): After the amplifier signal first passes the ...
Pertinence: 46%
Pages
aperture : horizontal = 12.6° Vertical = 11.8° Today, D20 is equiped with a 1600 cell (1997/98), respectiveley a 1536 cell (since 2000) curved position sensitive detector (PSD) filled with a mixture of 3He ... detection cells and high stability of counting rate and definition. Height : 150 mm, Radius 1471 mm Angular aperture : horizontal = 160° ...
Pertinence: 37%
Pages
best in the wavelength range 0.8 to 2.4 Å. D19 works most efficiently for unit cell volumes between 1000 and 100,000 Å3 i.e. cell edges from say 10 to 50 Å. Experiments requiring wavelengths below 0.8 Å are
Pertinence: 35%
Pages
with the only instrument capable of surveying reciprocal space for small samples with large unit cells, for d-spacings from 100Å to 0.5Å. The instrument has proven applications in biology, chemistry, physics ... single crystal diffraction data to atomic resolution from small samples with relatively large unit cells; it is also the only instrument ...
Pertinence: 19%
Pages
Fe/Si mirror analyzer for specular reflection (up to 99.9% efficient, wavelength dependent) 3 He gas cell polarizing analyzer (covering the detector solid angle) for off-specular reflection Radio Frequency
Pertinence: 20%
Pages
binning denominator mm per x-pixel mm per y pixel 105 Kiethley ext. temp Humidity Cell Sample temperature 110 Humidity Cell Regulation temperature Humidity 115 120 125 FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF ... neutron measurement; repeat above step 5-9 for additional runs with changed contents of the cell, changed cells etc. Before leaving the pump ...
Pertinence: 20%