ve detectors, with a cell spacing of 2.5 mm. The distance between sample and detection surface is 1146 mm, giving an angular spacing of 0.125º per cell. Each detector of 64 cells covers therefore 8º in ... typically cylindrical Geometry 20 mm diameter by 50 mm height (max. values) Microstrips detectors 9 x 64 cells under 15 bar of 3 He detectors ...
Recherche
Recherche de cell.
429 résultats ont été trouvés en 4 millisecondes.
Affiche les résultats de 31 à 40 sur 429.
Pages
Pertinence: 42%
Pages
The intensity of the scattered neutrons is measured by an array of nine microstrip detectors (64-cell, 3 He).
Pertinence: 37%
Pages
are identified by detector and detector cell number. After reading in one or several numor files, d4creg regroups or rebins the counts of all the 9*64 detector cells so as to produce one diffractogramme file ... format: scattering_angle counts sigma taking into account the detector efficiencies and possible bad cells, and optionally taking into ...
Pertinence: 25%
Pages
trajectories, FIGARO is less well suited for the study of relatively small solid/liquid interface cells (i.e. 5 cm or less). A particularly useful feature of FIGARO, however, is the ability to gain flux
Pertinence: 22%
Pages
surface layer, the size of the solid crystal and the instrument settings used. For typical sample cells and instrument configurations, a minimum reflected signal of 5 x 10 -7 or 1 x 10 -6 after background
Pertinence: 30%
Pages
surface pressure can be automated among neutron data acquisitions. Solid/liquid interface cells Solid/liquid interface cells are used to investigate the structure and composition of thin molecular films immersed ... development is the production of two sets of reflection up/down cells compatible with 80 x 50 mm (see picture right) or 50 x 50 mm ...
Pertinence: 38%
Pages
Sample environments Sample changer, Electromagnet, Cryostat, Cryomagnet, Furnace, Stopped-flow, Shear cell Detectors Sample - Detector distances 1.2 ... 12.8 m Detector 1 (rear): Single panel monoblock 640
Pertinence: 27%
Pages
can supply upon request: standard dilution or He3 fridges, furnaces, pressure cells (gas cells up to 5 kbar, clamped cells up to 30 kbar), vertical field cryomagnets 6 and 15 T, horizontal field cryomagnet ... neutrons, in the incident wavelength range 1 - 3 Å. It can support large sample environments (pressure cells, up to 30 kbar, high field ...
Pertinence: 43%
Pages
selector bunker, and a radio-frequency spin flipper close to the sample zone. Tests with a 3He polariser cell have been perform to allow for polarisation anlysis. For details, see here. Sample position The sample
Pertinence: 20%
Pages
Robot A robot arm for manipulating radioactive (and other) samples 5. Experiments 5.1. Proliferating Cell Nuclear Antigen (PCNA) P. Schurtenberger et al. (1998) J. Mol. Biol. 275, 123-132 5.2. The diffusion
Pertinence: 21%
