mainly used to investigate very slow collective movements. The relaxation times and the distances that can be accessed with IN15 are 0.001 to 1000 ns and 1 to 500 Å respectively, making IN15 the highest resolution
Recherche
Recherche de cane.
658 résultats ont été trouvés en 4 millisecondes.
Affiche les résultats de 321 à 330 sur 658.
Pages
Pertinence: 14%
Pages
dynamical features of macromolecular compounds in the μeV energy region, but scientific applications can be also found in areas of materials science, solid-state physics, geophysics and chemistry. Biology
Pertinence: 14%
Pages
The beamtime is shared amongst the collaborating partners and users can apply for beamtime via the respective institutes. Users can choose between different sample environment equipments, e.g., high and ... very competitive approach for using high ki values (i.e. ki=3.5-5Å -1 ). The instrument therefore can be easily used in the standard ...
Pertinence: 15%
Pages
layout The complete diffraction pattern at 1536 positions, covering a scattering range of 153.6°, can be obtained in a matter of seconds, and followed as a function of temperature, pressure or other parameter
Pertinence: 14%
Pages
spectrometer worldwide with the monochromatic flux at the sample up to 10 9 neutrons/cm 2 /s where users can perform demanding experiments not possible anywhere else. In recent years, the IN8 spectrometer has ... variable focusing accumulated over the last decades. The new device includes four crystal faces that can be alternatively set in Bragg ...
Pertinence: 15%
Pages
27 Å -1 (reflection down) for horizontal samples, and an even broader q-range can be achieved for solid samples which can be tilted using one of the sample goniometers. The sample area includes an active
Pertinence: 16%
Pages
over a large Q-range. Combining very high counting-rate stability with very low background counts, D4 can determine the local atomic structure of disordered materials (liquids, amorphous solids, nano-structured
Pertinence: 13%
Pages
cold neutron imaging instrument with additional X-rays imaging capabilities. These two modalities can be operated simultaneously. The typical configurations allow neutron radiography and tomography with ... available by means of a double crystal monochromator as well as a velocity selector. Additional equipment can be installed along the beam to ...
Pertinence: 15%
Pages
neutrons to NeXT. After the HOPG crystal (0.8 degrees mosaicity), there is a second aperture that can be closed step-less to reduce the collimation ratio. Flight tubes minimise air activation and scattering ... images under different projection angles to be acquired) approx. 4.5 m from this second aperture and can be translated along the beam ...
Pertinence: 15%
Pages
holography Instrument layout Because of the short neutron wavelength very small atomic displacements can be identified, accurate to typically 0.001 Å. D9 is equiped with a two-dimensional multidetector for