read/erase system Neutron image plate Gd 2 O 3 doped BaF(Br.I):Eu 2+ Radius 160 mm Length 400 mm Active area 1000 x 400 mm 2 Pixel size 100, 200, 400 µm 2 Sample environment (1) Ambient or (2) Oxford
Recherche
Recherche de activation.
179 résultats ont été trouvés en 3 millisecondes.
Affiche les résultats de 21 à 30 sur 179.
Pages
Pertinence: 31%
Pages
5 cts per minute 2 dim. position sensitive 3 He detector distance to sample (variable) 1.3 - 6 m active area 30 x 30 cm 2 efficiency 76 % resolution 2.8 mm (FWHM) Polarisation and polarisation analysis
Pertinence: 25%
Pages
double-focusing active area: 180 mm x 140 mm (W x H) Cu (200) variable double-focusing active area: 180 mm x 140 mm (W x H) Si (111) bent perfect crystals, variable double-focusing active area: 160 mm x ... v) Multianalyser Flatcone Analysers 31 Si111 bent perfect crystals, fixed curvature for kf=3 A -1 active area 20 mm (W)x variable up to 60 mm ...
Pertinence: 34%
Pages
in stroboscopic mode. Today, up to 256 complete diagrams or slices can be recorded, with a minimum active counting time window (open gate ) of 1 µs inside each slice of at least 30 µs (so a maximum slice
Pertinence: 16%
Pages
Main characteristics of FlatCone active pixel width 1.3 deg. no. of pixels 31 angular coverage 75 deg. SA distance 765 & 1000 mm analyzer crystals Si 111 cold neutrons k f = 1.4 Å -1 ΔE = 0 - 10 meV thermal
Pertinence: 26%
Pages
also been implemented even counting times are relatively long. The sample stage is equipped with active and passive anti-vibration systems, x-y-z translation axis, goniometer for solid samples. An optical
Pertinence: 19%
Pages
D22 possesses the largest area multidetector ( 3 He) of all small-angle scattering instruments (active area 1 m 2 ), with a pixel size of 0.8 x 0.8 cm, i.e. 16 K resolution elements. The detector consists
Pertinence: 17%
Pages
380 mm, 420 mm oscillation ± 1° Detector type 2-dimensional Position Sensitive microstrip Detector active area 25 x 25 cm 2 readout 256 x 256 pixels angular step 0.04° (at 1 m sample-detector distance) distance
Pertinence: 21%
Pages
They can also be used to ensure medications are more efficient, by informing the development of active ingredients for better drugs. This research into catalysts remains extremely valuable, especially ... manufacturing process – will be able to perform more efficient reactions to support the development of active ingredients in drugs, helping to ...
Pertinence: 27%
Pages
some Laue zones Use the Zone tool in the Laue Plane window to define some Laue zones. With the tool active, click on a peak position and drag to another peak on the same trajectory. A line will appear on
Pertinence: 16%
