The prototype cell was tested successfully on D11 in June and July 2015 and several versions are being manufactured: 50 MPa for Spin-Echo providing Ø30 mm incident beam access (see cell 22PL05AO4 ) 300 ... This 300 MPa (3 kbar) cell was designed within the framwork of NMI3-II . The prototype is essentially made from hardened CuBe alloy and Sapphire ...
Recherche
Recherche de cell.
432 résultats ont été trouvés en 4 millisecondes.
Affiche les résultats de 261 à 270 sur 432.
Pages
Pertinence: 100%
Pages
mK stability). The cell was tested successfully on IN15 in March 2017 (photo below). The transmission is 6Å cell 87% at 6 Å, 79% at 10 Å and 69% at 16 Å. Several variations of this cell have been produced ... providing Ø30 mm incident beam access (this cell) 300 MPa for SANS providing Ø10 mm incident beam access (2 copies, see cell 21PL30AO2 ) 500 ...
Pertinence: 100%
Pages
This cell is made from the aluminium alloy 7049A-T6 and provides a Ø6 x 60 mm 3 sample volume, i.e. 1.85 ml. The pressure is generated using a hydraulic press with or without external separator. The maximum
Pertinence: 100%
Pages
This cell is made from TiZr alloy and provides a Ø6 x 62 mm3 sample volume, i.e. 1.75 ml. A separator may be used when the amount of available sample is low (1.3 ml required). The pressure is generated
Pertinence: 100%
Pages
This cell is made from hardened CuBe and provides a Ø6 x 65 mm3 sample volume i.e. 1.8 ml. A separator may be used when the amount of available sample is low (1.3 ml required). The pressure is generated
Pertinence: 100%
Pages
This cell is made from TiZr alloy and provides a Ø12 x 44 mm3 sample volume, i.e. 5 ml. The pressure is generated using a hydraulic press with or without separator. The maximum pressure is 700 MPa, i.e
Pertinence: 100%
Pages
This cell is made from the aluminium alloy 7049A-T6 and provides a Ø12 x 42 mm3 sample volume, i.e. 4.7 ml. The pressure is generated using a hydraulic press with or without separator. The maximum pressure
Pertinence: 100%
Pages
AW 7049A-T6. This cell is generally used on IN16B but can be also used on other instruments with or without the electrodes and dedicated sample stick. A complete description of the cell is provided in the ... This cell is designed to simultaneously measure the dielectric properties of the sample. It is mostly made from the aluminium alloy 7049A-T6 ...
Pertinence: 100%
Pages
for the cell body, there is very little coherent scattering. The maximum sample dimensions vary with cells and pressure ranges. Most cells fit into standard "Orange" cryostats. These pressure cells are available ... In these cells the pressure is continuously adjusted from 0 to Pmax while the sample is in the beam. The cell is linked via a flexible ...
Pertinence: 100%
Pages
solar cells Universidad Autónoma de Madrid J.A. Alonso M.T. Fernandez-Diaz Carmen ABIA SANZ 2019.09.01 2023.04.18 191_21 MAT Energy materials: Electrolytes and cathodes for solid oxide fuel cells Durham ... Kenny PADRON ALEMAN 2023.07.01 ESP-1-2023 B&H, NPP Biological response to neutron irradiation of cells for new approaches in Boron Neutron ...