Suite à l’accident de Fukushima, l’ASN a imposé aux exploitants nucléaires : 1. La prise en compte d’agressions externes extrêmes, significativement plus fortes que celles initialement retenues pour le ... de systèmes permettant de prévenir ce risque de fusion dans les situations « noyau dur » extrêmes : 1. ARS : arrêt réacteur sismique Ce système ...
Recherche
Recherche de 1'".
1022 résultats ont été trouvés en 4 millisecondes.
Affiche les résultats de 241 à 250 sur 1022.
Glossary
Pertinence: 12%
Pages
Designed and built by the LNCMI-Toulouse , the coil produces a horizontal field up to 40 T with the 1.15 MJ transportable power supply. The coil is installed inside a cryostat developed by our team. As ... beam. Cradle attached to the cryocooler ©Ecliptique - L. Thion Langmuir trough Based on a Microtrough G1 by Kibron , this Langmuir trough is ...
Pertinence: 11%
Pages
pressure controller 700 MPa He pressure controller 700 MPa liquid stick controllers 1 GPa gas pressure controllers 1 GPa liquid pressure controllers
Pertinence: 16%
Pages
rings with a total thickness of 34 mm within the 130° horizontal openings. This magnet features two 1.5W@4.2K cryocoolers dedicated respectively to the coils and the liquid-helium reservoir. It has a very ... variable temperature insert (VTI) allowing the sample to be maintained at any temperature between 1.5 and 300 K. Temperatures down to 40 mK ...
Pertinence: 16%
Pages
We also propose several pressure transmiting media: helium, FC-770, methanol:ethanol mixture, etc. 1 GPa TA6V/CuBe2 cell during frettage in the blast room Find out more Clamped Cells Gas Pressure Cells
Pertinence: 12%
Pages
the relaxation time of the 3He polarisation was better than 100 hours in the 1.9 litre cell (alias TetraPack ) filled at 1.2 bar [ more ]. Polarimetric NSE demonstrated On a standard spin-echo spectrometer
Pertinence: 14%
Pages
Comment 01IL1VA10 4.2 - 320 10 H2, He, N2 Sieverts method, 1 gas 02HI2VA20 4.2 - 500 20 (1 litre max.) H2, O2, He, N2, CH4, CO2, D2O Sieverts method, He + 2 gases 03HI2VA20 4.2 - 500 20 (1 litre max.) ... dosing at 20 MPa = (1 litre - capillary vol - sample cell/stick vol). Three dosing volumes are included with the minimum at 10 cc and the maximum ...
Pertinence: 18%
Pages
Comment IN1 - Lagrange 213ILGI49 1.5 - 550 80 Ø49 ANSTO-HZB-ILL design 213ILGI70 1.5 - 320 80 Ø70 ANSTO-HZB-ILL design IN8 237ILGI70 1.5 - 320 80 Ø70 ANSTO-HZB-ILL design IN11 236ILGI49 1.5 - 320 3 Ø49 ... for PT cooler 205ILGI49 1.5 - 320 3 Ø49 single capillary and Quartz cell 223ILGI49 1.5 - 550 200 Ø49 ANSTO-HZB-ILL design 231ILGI70 1.5 - 550 ...
Pertinence: 18%
Pages
temperature gradients. Long-term temperature stability is typically 0.1 % of the actual temperature and gradients are in the order of 0.1 to 0.5% of the actual temperature. The length of the heater element
Pertinence: 13%
Pages
in stock at the ILL. Long-term temperature stability is typically 0.1 % of the actual temperature and gradients are in the order of 0.1 to 0.5% of the actual temperature. The length of the heater element ... Laboratory. Instrument Code Max. Temperature (°C) Material in the beam Sample Dimensions Ø x height (mm) D1B 17TL13AV20 1000 Al - V Ø15 x 50 ...
Pertinence: 15%
