through which samples and sample-environment devices are installed on the instrument. incident neutron beam sample position small angle analyser made of CaF 2 (422) cystals large angle analysers made of CaF
Recherche
Recherche de beams.
388 résultats ont été trouvés en 3 millisecondes.
Affiche les résultats de 211 à 220 sur 388.
Pages
Pertinence: 23%
Pages
and examine processes therein. (pdf - 207 Ki) Click to enlarge How do I access ILL's instruments? Beam time at the ILL can be obtained in different ways , but is typically arranged via the standard submission ... neutron instrumentation and the expertise of its scientific and technical staff. Industrial access to beam time can also be fully ...
Pertinence: 20%
Pages
for his development of a perfect-crystal neutron interferometer. It splits a neutron beam into two coherent sub-beams which are spatially separated by several centimeters and are then recombined again showing
Pertinence: 20%
Pages
imaging, that can see inside materials and examine processes therein. White beam imaging is based on the attenuation of the neutron beam, due to absorption or scattering, through an object. Tomography is performed ... techniques and what can they do for science. What is a neutron? The uniqueness of neutrons When beams of neutrons are used to probe ...
Pertinence: 20%
Pages
between the monochromator shielding and the edge of the cryomagnet (distance measured on the incident beam axis). 300 mm is presently the standard distance on this instrument. When the sample table is pushed
Pertinence: 21%
Pages
continuous polychromatic neutron flux from the neutron guide H16 is turned into a pulsed monochromatic beam by a set of 6 choppers. the monochromatic neutron bursts are inelastically scattered by the sample
Pertinence: 21%
Pages
blocks of the primary spectrometer and the surface of the cryomagnet (on the incident beam axis and at the height of the beam) must be 1375 mm for the 15 T magnet and 950 mm for the 12 T magnet. (jpg - 332 Ki)
Pertinence: 26%
Pages
sample. Why aerodynamic (gas flow) levitation of the sample ? No container windows in the neutron beam and hence no additional background. Why laser heating ? No sample contamination by hot vapor from
Pertinence: 19%
Pages
under 6 metres of water. Replacement of the H1H2 Beam tube - long version - 2022 Replacement of the H1H2 Beam tube - short video Turning over the H1-H2 beam tube DrE H1-H2 - divers in the pool Timelapse Guide ... guide/Carter Pink mechanical assembly being lifted towards the H1-H2 beam tube Now that this assembly has been inserted into the beam ...
Pertinence: 25%
Pages
under 6 metres of water. Replacement of the H1H2 Beam tube - long version - 2022 Replacement of the H1H2 Beam tube - short video Turning over the H1-H2 beam tube DrE H1-H2 - divers in the pool Timelapse Guide ... guide/Carter Pink mechanical assembly being lifted towards the H1-H2 beam tube Now that this assembly has been inserted into the beam ...
Pertinence: 25%