ILL provides 3 high-pressure volumetric gas sorption analysers and 14 injection sticks for Orange cryostats. Sieverts (volumetric) sorption analyser We propose two volumetric sorption analysers from Hiden
Recherche
Recherche de ILL.
1238 résultats ont été trouvés en 3 millisecondes.
Affiche les résultats de 201 à 210 sur 1238.
Pages
Pertinence: 14%
Pages
ILL provides 23 furnaces that are available from a pool or assigned to instruments. The maximum allowable temperatures range from 250 to 1650°C. All repairs and modifications are carried out in the Hi
Pertinence: 12%
Pages
000 litres per day at 40 Tesla. A standard ILL cold-valve regulates the He flow brought to the sample through a Torlon/Sapphire heat exchanger developed at ILL to avoid eddy currents and reduce neutron ... Temperatures down to 40 mK are accessible with an ILL dilution insert. The access in the horizontal plane is defined by a two-pillar design ...
Pertinence: 19%
Pages
sticks . Most of them are available from the pool on request. Sufficient advance notice to sane(at)ill.fr is required for their reservation and preparation. The use of pressure equipment is under the r
Pertinence: 14%
Pages
ILL provides 67 cryostats , 21 cryofurnaces , 17 special sample sticks and 19 dilution refrigerators. Cernox, RhFe and Pt100 thermometers Since 2007, we have calibrated and installed more than 700 Cernox ... is available from the cryostat web page. A curve is also displayed for convenience. LIQUID CRYOGENs ILL has been operating a He recovery ...
Pertinence: 18%
Pages
After this development phase at HCB on SPAN, the Polarimetric NSE technique has been commissioned at ILL on IN15 [ more ]. Spherical Neutron Polarimetry simulations If you wish to better understand the behaviour
Pertinence: 13%
Pages
humidity up to 99.9% with an accuracy of ±0.01% RH. Three identical chambers are available at the ILL on D16 where d-spacings can be measured after short or long equilibration times. Sample alignement ... other neutron techniques, in particular small angle scattering and reflectometry. Stopped-flow systems ILL owns stopped-flow devices to ...
Pertinence: 15%
Pages
on request. Sufficient advance notice to sane(at)ill.fr is required for their reservation and preparation. The first unit was designed and built at the ILL and the two others were acquired from Hiden Isochema ... of 0.006 µmoles when operating with the 10 cc volume. The sample temperature is controlled using ILL-supplied temperature environment ...
Pertinence: 16%
Pages
5 - 550 200 Ø49 ANSTO-HZB-ILL design 231ILGI70 1.5 - 550 200 Ø70 ANSTO-HZB-ILL design 242ILGI70 1.5 - 550 200 Ø70 ANSTO-HZB-ILL design 243ILGI49 1.5 - 550 200 Ø49 ANSTO-HZB-ILL design Sticks for gas injection ... - Lagrange 213ILGI49 1.5 - 550 80 Ø49 ANSTO-HZB-ILL design 213ILGI70 1.5 - 320 80 Ø70 ANSTO-HZB-ILL design IN8 237ILGI70 1.5 - 320 80 Ø70 ...
Pertinence: 20%
Pages
denote the internal ILL order number. This number is incremented each time a new device is made available, the first and second letters denote the code of the manufacturer as follows: IL : ILL Stick or sorption ... analyser. For example, the injection stick 184ILHP49 is the 184th item of equipment introduced at the ILL. It was designed and built by ...