HI : Hiden Isochema for sorption analysers, a digit is added to reflect the number of gases that can be mixed, the following letters denote the code of the sorption mode: VA : Volumetric sorption analysis
Recherche
Recherche de cane.
658 résultats ont été trouvés en 3 millisecondes.
Affiche les résultats de 191 à 200 sur 658.
Pages
Pertinence: 13%
Pages
letters denote the code of the type as follows: TL : ILL standard top-loading furnace BD : body that can be dismounted MF : mirror furnace SA : with silicon or aluminum windows the third and fourth numbers ... 17TL13AV20 is the 17th furnace introduced at the ILL. It was designed and built by our staff (code TL), can be used up to 1300K (or about ...
Pertinence: 16%
Pages
pressures up to 30 kbar. Temperatures from 40 mK to 320 K, with single crystal, powder or liquid samples can be achieved depending on the cell. Clamped cells are loaded to the desired pressure in a press and ... transferred into the neutron beam (directly or inside a cryostat). The pressure transmitting medium can be a liquid such as "fluorinert" ...
Pertinence: 15%
Pages
In these cells, the pressure can be continuously adjusted from 0 to Pmax while the sample is in the beam. The cell is linked via a 'flexible' high-pressure capillary to a gas pressure generator located ... dimensions vary with cells and pressure ranges. Most cells fit into standard "Orange" cryostats . The ILL can supply a complete system including ...
Pertinence: 14%
Pages
or a high-pressure syringe, which is located several metres away. The pressure transmitting medium can be "fluorinert" (a fluorocarbon), deuterated hydrocarbon or alcohol (such as iso-propanol). When null ... sample sticks to avoid blockages. In this specific case, only clamps or cells with an in-situ separator can be used. Main body in Aluminium ...
Pertinence: 11%
Pages
sample sticks to avoid blockages. In this specific case, only clamps or cells with an in-situ separator can be used. Code Temperature Range (K) Maximum Pressure (kbar) Calorimeter Ø (mm) Type, Comment 187ILHP49 ... sample volume with an annular space under vacuum. Optionally, coaxial cables, wires or optical fibres can be brought to the sample ...
Pertinence: 13%
Pages
of a tough stainless steel. Relatively fast speeds can be used with the respective feeds and depth of cut being kept small. Tipped cutting tools can be employed. A continuous supply of coolant must be ... however, should be kept below 750°C because the TiZr alloy starts to soften and recrystallization can occur leading to Bragg peaks. Production & ...
Pertinence: 16%
Pages
temperatures can be achieved at the push of a button. These ILL dry "Orange" cryostats use cold-heads which employ mostly the Gifford-McMahon refrigeration cycle. The Ø70 top-loading cryostats can host a Ø49 ... dimensions and uses. The standard sample access dimensions are of Ø50, 70 and 100 mm. All orange cryostats can be supplied with helium and ...
Pertinence: 11%
Pages
. With the sticks 156ILEF49 , 210ILEF49 , 257ILEF49 , 266ILEF09 and 281ILEF49 , an electric field can be applied in a vacuum space once the sample has been cooled down with exchange gas. The maximum applied ... thermometer located near the sample in the exchange gas. With the stick 240ILUP12 a low vertical force can be applied onto the sample ...
Pertinence: 13%
Pages
orange cryostat and a dedicated stick. This stick features an isothermal copper block on which we can mount up to 21 thermometers and 4 standard reference thermometers. The standard thermometers are mounted ... the cryostat used). We also produce a plot of the calibration curve in PNG format. On request, we can also supply the fitting parameters of ...
Pertinence: 15%
