cradles for orienting the sample crystals, with the detector moving in a horizontal plane. Normal-beam diffractometers have a mechanism for tilting the counter out of the horizontal plane, thus enabling
Recherche
Recherche de beams.
388 résultats ont été trouvés en 2 millisecondes.
Affiche les résultats de 181 à 190 sur 388.
Pages
Pertinence: 11%
Pages
kinds of scientific studies, which depends for example on the energy and flux of the incident neutron beam, polarized neutron capability and the availability of specific sample environments. IN1 TAS/LAGRANGE ... high energy resolution using the change in polarization between the incident and scattered neutron beams to measure small energy changes ...
Pertinence: 15%
Pages
reciprocal space, while reducing the background on the detector compared to use of the full white beam.
Pertinence: 21%
Pages
Instrument layout Here the instrument is shown in its classical setting for magnetic studies. The neutron beam is polarised and the sample is placed in the high magnetic field of a cryomagnet.
Pertinence: 20%
Pages
The instrument and its team The principle of the filling station Polarised neutron beams are essential for certain fields of research, such as the study of the magnetism of matter. Neutrons can be polarised ... the instrument can be configured into virtually any shape homogeneous polarisation over the entire beam section sufficiently wide ...
Pertinence: 26%
Pages
Instrument layout The coldneutron beam is represented by a green arrow labeled CN. a: the 100-L liquid helium bath b: the needle valve c: the 1-K pot d: the 4 He superleak e: the 3 He pumping column f:
Pertinence: 22%
Pages
available through transnational access thanks to RADNEXT project of which ILL & IRTNanoelec are partners. Beam characteristic: Fission spectrum below Flux (25 meV equivalent at nominal reactor power 58.3 MW) :
Pertinence: 23%
Pages
neutron source (HCS) of the ILL and optimized neutron optics Clean beam (velocity selector etc) and very low background Flexible choice of beam conditions (different monochromators, analyzers, guides) Routine
Pertinence: 24%
Pages
type interferometer for thermal neutrons. The neutron beam is split into two beam paths which are separated macroscopically in the order of 5cm. The beams are recombined and their interference fringes are ... are measured, revealing the quantum mechanical phase shift between the two beams. Applications Demonstration of basic quantum physics laws ...
Pertinence: 28%
Pages
distribution of the products of thermal-neutron-induced nuclear fission at very high resolution. The beam intensity at the separator also makes it possible to detect γ-rays, conversion electrons, β-rays and
Pertinence: 21%