original specifications were defined for the study of structures of a few nm periodicity diffracting to a real space resolution of a fraction of nanometer, making it perfectly suited to membrane diffraction ... seventies. The new instrument was commissionned in 2023 after a major upgrade that consisted in the replacement of the former detector ...
Recherche
Recherche de a.
1447 résultats ont été trouvés en 4 millisecondes.
Affiche les résultats de 181 à 190 sur 1447.
Pages
Pertinence: 13%
Pages
to achieve 7 attenuation factors f a : f a =4.63 (att 1), f a =16.9 (att 2), f a =72.7 (att 3) f a =77.7 (att 1 + 2), f a =348 (att 1 + 3), f a =1165 (att 2 + 3) f a ≈8200(att 1 + 2 + 3) Sample area flux ... former CERCA 3He detector of D22). This detector has a considerably larger counting area thus a much better dynamic range, a better efficiency ...
Pertinence: 18%
Pages
Lindner P. (2006) ILL Technical Report ILL 06 LI 03T (pdf - 0.95 Mi) Lindner P., May, R.P., Timmins P.A. (1992) Physica B180 & 181 , 967-972, DOI:10.1016/0921-4526(92)90524-V Ibel K. (1976) J. Appl. Cryst
Pertinence: 9%
Pages
phenomena. This compound shows a transition where charges localize and this change in the electronic behaviour is accompanied by a structural phase transition. The 2D-detector of D9 is a valuable advantage for ... and the magnetic ordering in similar manganites. A D9-like diffractometer is the best tool for this purpose. Ref.: A. Daoud-Aladine et ...
Pertinence: 13%
Pages
neutron diffraction over a range of temperatures from 5 to 295 K. We show that a considerable improvement occurs by representing the internal modes by a single second-rank tensor and that a further improvement ... improvement follows by including a Grüneisen parameter to account for volume thermal expansion. By applying the treatment to ...
Pertinence: 13%
Pages
constitutes a novel technique to obtain structural information. It is based on the recording of the interference of neutron waves coherently scattered by atoms located on a crystal lattice with a suitable ... Reconstructed hologram from a spherically shaped single crystal of Pb0.9974Cd0.0026.The x-axis is along the incident neutron beam. The spots ...
Pertinence: 13%
Pages
cradle can be equipped with a helium-flow cryostat (1.6 K to 450 K, or 0.1 K to 10 K in dilution mode), or a hot-air furnace (up to 1000 K), both with full four-circle accessibility. A double-mirror furnace ... raphic studies of nuclear and magnetic structures. In addition the optional energy analysis allows a restricted energy window to be set to ...
Pertinence: 12%
Pages
size of a ROI can be modified by dragging it by its lower-right corner. A left-click (right-click) on either of these two corners activates (deletes) a ROI. option to export all parameters of a 'Fit range' ... Rplot Rplot is a simple program to visualize D10 (and other ILL single-crystal diffractometers) raw data. Rplot is distributed under the ...
Pertinence: 12%
Pages
INCR=6,MASK=w60) ; 5) Calculate random raw data with the expected bckg counting rate ; averaged in a pixels window (kernel) w4=raw_bck(w2,bck_ch=[1500,1600],mask=w60,kernel=[9,6]) ; 6) Calculate S(Q,w)
Pertinence: 8%
Pages
methanol at T = 298 K at Q= 0.4 and 10 nm-1. The red line is the result of a linear combination of the simulation (blue dots connected by a solid line) and multiple scattering (green dashes) data to the experimental ... microscopic behaviour. For this reason, after a thorough experimental, computational and theoretical scrutiny, the dynamics of ...
Pertinence: 13%
