mK stability). The cell was tested successfully on IN15 in March 2017 (photo below). The transmission is 6Å cell 87% at 6 Å, 79% at 10 Å and 69% at 16 Å. Several variations of this cell have been produced ... providing Ø30 mm incident beam access (this cell) 300 MPa for SANS providing Ø10 mm incident beam access (2 copies, see cell 21PL30AO2 ) 500 ...
Recherche
Recherche de cell.
432 résultats ont été trouvés en 1 millisecondes.
Affiche les résultats de 171 à 180 sur 432.
Pages
Pertinence: 100%
Pages
The prototype cell was tested successfully on D11 in June and July 2015 and several versions are being manufactured: 50 MPa for Spin-Echo providing Ø30 mm incident beam access (see cell 22PL05AO4 ) 300 ... This 300 MPa (3 kbar) cell was designed within the framwork of NMI3-II . The prototype is essentially made from hardened CuBe alloy and Sapphire ...
Pertinence: 100%
Pages
This cell is made from hardened CuBe and provides a Ø6 x 60 mm3 sample volume, i.e. 1.7 ml. A separator may be used when the amount of available sample is low (1.2 ml required). The pressure is generated
Pertinence: 100%
Pages
This cell is made from the aluminium alloy 7049A-T6 and provides a Ø6 x 60 mm3 sample volume, i.e. 1.7 ml. A separator may be used when the amount of available sample is low (1.2 ml required). The pressure
Pertinence: 100%
Pages
This cell is made from TiZr alloy and provides a Ø6 x 60 mm3 sample volume, i.e. 1.7 ml. A separator may be used when the amount of available sample is low (1.2 ml required). The pressure is generated
Pertinence: 100%
Pages
This cell is made from the aluminium alloy 7049A-T6 and provides a Ø6 x 60 mm3 sample volume, i.e. 1.7 ml. A separator may be used when the amount of available sample is low (1.2 ml required). The pressure
Pertinence: 100%
Pages
This cell is made from the aluminium alloy 7049A-T6 and provides a Ø12 x 56 mm3 sample volume, i.e. 6.3 ml. A separator may be used when the amount of available sample is low (6 ml required). It can also
Pertinence: 100%
Pages
This cell is made from hardened CuBe and provides a Ø12 x 56 mm3 sample volume, i.e. 6.3 ml. A separator may be used when the amount of available sample is low (6 ml required). It can also be provided
Pertinence: 100%
Pages
maximum pressure is 250 MPa, i.e. 2.5 kbar up to 100°C. Sketch of the TiZr cell in the beam (pdf - 1.18 Mi) Drawing of the TiZr cell - Click on the image to download the corresponding PDF file ... This cell is made from TiZr alloy and provides a Ø12 x 56 mm3 sample volume, i.e. 6.3 ml. A separator may be used when the amount of available sample is ...
Pertinence: 100%
Pages
This cell is made from TiZr alloy and provides a Ø12 x 56 mm3 sample volume, i.e. 6.3 ml. A separator may be used when the amount of available sample is low (6 ml required). It can also be provided with ... without separator. The maximum pressure is 600 MPa, i.e. 6 kbar up to 100°C. Dimensions of the TiZr cell in the beam Aluminium inserts making ...