Calibration A very simple detector efficiency calibration consists simply in measuring a vanadium or a plexiglass sample to obtain a nearly flat background. A Two-Theta scan has to be performed to obtain a the ... not monitor-controlled. You may perform a simple acquisition, a scan or a coupled scan (moving one or two motors between the steps of a ...
Recherche
Recherche de a.
1447 résultats ont été trouvés en 7 millisecondes.
Affiche les résultats de 171 à 180 sur 1447.
Pages
Pertinence: 13%
Pages
displacements can be identified, accurate to typically 0.001 Å. D9 is equiped with a two-dimensional multidetector for a more accurate and secure data collection.
Pertinence: 11%
Pages
with no sample mounted and no sample environment. In practice D9 is often used with the cold head of a cryocooler passing through the φ-ring of the eulerian cradle.
Pertinence: 10%
Pages
Cradle is the central part of a 4-circle diffractometer such as D9. Two circles, denoted φ and χ, are used to adjust the crystal orientation relative to the diffractometer axes. A third circle, ω, sets the ... closed Eulerian Cradle of D9 is stout enough to accommodate sample environment devices such as a cryocooler, a closed shell furnace, etc.
Pertinence: 13%
Pages
normally takes a few minutes, and recording of a full set of data a few days. If the crystal is studied as a function of temperature, pressure or other, the total measurement time is about a week. ... reactor in the world. The monochromator is a Cu crystal in transmission geometry using the (220) planes. The instrument is placed on a Tanzboden ...
Pertinence: 13%
Pages
rotates on a gamma-arm (γ=2θ in the equatorial plane), on air cushions. The present sample orienter is a C-shaped Eulerian cradle with offset phi axis. This allows a larger range in omega than a conventional ... distance of 76 cm 0.19° horiz. x 0.12° vert. Instrument Description D19 is a single-crystal and fibre diffractometer, which incorporates a ...
Pertinence: 13%
Pages
exposed to a neutron beam for 1 day at an intensity comparable to that on HIPD with LANSCE operating at 100mA. They are augmented by calculations from NIST of the activation from a 1-day exposure to a 10 7 n/s-cm ... Miscellaneous D19 - Introduction D19 is a diffractometer combining a high flux monochromatic neutron beam and a large area detector ...
Pertinence: 21%
Pages
realised by a double chopper system with variable phase. The useful wavelength range is from 2-30 Å; the upper limit set by a frame overlap mirror. In the case of the polarised TOF mode a wavelength range ... range of 4-20 Å is polarised by a S-bender. For monochromatic operation, a fixed wavelength of 5.5 Å with a base resolution of 4% (FWHM) is ...
Pertinence: 13%
Pages
rare macromolecules. The example below shows a time dependent study of the interaction between a lipid film and the enzyme 'phospholipase A2' from cobra venom in a heavy water solution. The enzyme attacks ... separation of the two correlations. This work was a result of a collaboration between F. Radu, H. Zabel and A. R. Wildes More details from F. ...
Pertinence: 21%
Pages
extracts the data between two x-pixels and projects on to the y-axis maskme applies a software mask to a dataset d17_save saves a workspace in an ascii format with relevant fields and headers d17_xyconvert will ... will ask you for a name for the new setting and create it in the upper left list of settings. The creation of the setting may take a ...
Pertinence: 20%