used on a polarised neutron instrument or inside a cryomagnet. Dimensions of the TiZr cell in the beam (pdf - 616 Ki)
Recherche
Recherche de beams.
401 résultats ont été trouvés en 3 millisecondes.
Affiche les résultats de 161 à 170 sur 401.
Pages
Pertinence: 23%
Pages
of these collisions are very small, the emitted neutrons are very close to the axis of the emerging beam. This process is thus referred to as Small Angle Neutron Scattering (SANS) In the animation below
Pertinence: 23%
Pages
Guide hall, thermal beam H25 distance reactor-core to monochromator : 65 m Monochromator crystal d-spacing (Å) k i (Å -1 ) flux (10 7 cm -2 .s -1 ) PG(002) 3.355 2.662 3.5 4.10 6.0 Heusler(111) 3.435 2 ... α 0 = 12.λ (Å) α 1 , α 2 , α 3 = 10', 20', 30', 40', 60' adjustable by Soller collimators Sample beam size LxH=5 x 4 cm 2 Analyser PG(002) ...
Pertinence: 23%
Pages
(written in C) that enables to model very precisely a neutron instrument described as a series of beam-line components. A source component shoots off each neutron randomly (Monte-Carlo), and the particle ... some virtual detectors along the neutron path, to monitor the characteristics and flux of the neutron beam at that position. McStas provides a ...
Pertinence: 23%
Pages
(written in C) that enables to model very precisely a neutron instrument described as a series of beam-line components. A source component shoots off each neutron randomly (Monte-Carlo), and the particle ... some virtual detectors along the neutron path, to monitor the characteristics and flux of the neutron beam at that position. McStas provides a ...
Pertinence: 23%
Pages
Instrument layout The coldneutron beam is represented by a green arrow labeled CN. a: the 100-L liquid helium bath b: the needle valve c: the 1-K pot d: the 4 He superleak e: the 3 He pumping column f:
Pertinence: 23%
Pages
distance distribution. To prove this, it is enough to deform a metal sample placed in an X-ray or neutron beam.
Pertinence: 23%
Pages
but the descending portion shows the presence of oscillations resulting from interference between beams reflected by the two surfaces. The size of these oscillations is related to the layer thickness. The
Pertinence: 23%
Pages
Reactor hall, beam tube H9 Sources 229 Th, 233 U, 235 U, 237 Np, 239 Pu, 241 Pu, 241 Am, 245 Cm, 249 Cf, 251 Cf flux at target position 5.3 · 10 14 n cm -2 s -1 horizontal aperture 2β ≤ 2.3° vertical aperture ... distribution in the products of thermal-neutron-induced nuclear fission at very high resolution. The beam intensity at the separator also ...
Pertinence: 23%
Pages
chapter "Neutron Optics" 1.1 Location of the diffractometer The PSD powder diffractometer D20 shares the beam tube H11 in the reactor (level C) with two other instruments: the PSD single crystal diffractometer ... described. A monochromator may be choosen by turning the changer in the protected monochromator and beam tube housing, muliple take-off ...
Pertinence: 22%