the typical measuring strategy of a three axis spectrometer like IN8. The monochromator selects a beam of neutrons in a narrow energy band. The analyser is positioned to select a scattering direction (related
Recherche
Recherche de beams.
388 résultats ont été trouvés en 2 millisecondes.
Affiche les résultats de 151 à 160 sur 388.
Pages
Pertinence: 23%
Pages
than 36m upstream a velocity selector in the guide placed on a movable in/out table ensures a clean beam, preventing higher order reflections from the monochromator and reducing the background at the sample
Pertinence: 14%
Pages
not corrected for higher order contributions. Orange curve: New IN12 with velocity selector in the beam, green curve: additional 60' collimation using only vertical focusing.
Pertinence: 23%
Pages
Computer drawing of UFO A simulation of UFO beam-trajectories Multi-analyzer IN12-UFO As a further option, IN12 will be equipped with a 2-dimensional position sensitive detector and an array of fifteen ... fifteen analysers which can be rotated and positioned individually in order to map the scattered beam on a user-chosen path in Q-space. ...
Pertinence: 26%
Pages
monochromator crystals which select an initial wavelength out of it, directing this beam onto the sample. The monochromatic beam arrives on the sample - for example a single crystal - and is scattered in many ... A simulated experiment The incident polychromatic neutron beam coming from the guide H144 passes in the standard set-up a velocity ...
Pertinence: 28%
Pages
177202-1/4. Example 2 IN12 has a dedicated vacuum tank used to suppress air scattering of the direct beam. This setup is efficient at low momentum transfer and may be competitive with time of flight instruments
Pertinence: 18%
Pages
through which samples and sample-environment devices are installed on the instrument. incident neutron beam sample position small angle analyser made of CaF 2 (422) cystals large angle analysers made of CaF
Pertinence: 23%
Pages
polychromatic neutron beam (wavelength around 2.2 Å) is backscattered on the monochromator (Bragg reflexion on a crystal lattice) with a high monochromaticity (energy resolution 10 µeV). The beam is reflected so
Pertinence: 26%
Pages
Cryocradle is now available to reduce beamtime losses by cooling a sample while the other is in the beam. Cradle attached to the cryocooler ©Ecliptique - L. Thion Langmuir trough Based on a Microtrough G1
Pertinence: 14%
Pages
temperatures (up to 3000 K). We have started building a prototype compatible with the use of polarised beams which can be installed in a few hours like a cryomagnet. It is also designed to be used in conjonction
Pertinence: 18%