Riley D.P., Kisi E.H., Phelan D. - SHS of Ti3SiC2: Ignition temperature depression by mechanical activation, J. European Ceram. Soc. 26 , 1051-1058 (2006). Riley D.P., Kisi E.H., Hansen T.C., Hewat A.W.
Recherche
Recherche de activation.
179 résultats ont été trouvés en 8 millisecondes.
Affiche les résultats de 151 à 160 sur 179.
Pages
Pertinence: 26%
Pages
crucial step in the reaction path is the co-ordination of an H2 molecule to the metal centre and its activation via the formation of a M(η 2 -H 2 ) complex, and the subsequent oxidative addition leading to a ... Figure) has also shown that the compound is not only stable at room temperature but also much more active for H/D exchange and C-C bond ...
Pertinence: 34%
Pages
Neutron scattering density of the active-site residues and water molecules involved in the interactions between the enzyme xylose isomerase and glucose A close-up view of the putative hydronium (D3O+) ... (D3O+) cationThis is in XI-apo hydrogen bonded to three active site residues Glu181, Glu217 and Asp245 of xylose isomerase. The 2Fo-Fcneutron ...
Pertinence: 33%
Pages
parameter c was not refinable for trigonal space groups in hexagonal setting when lattice constraints are active Bugfixes 10/09 (v4.0.2): mixed refinements including powder data followed by removing the powder ... n vector finder window; transferring a MSG from the spacegroup tables window to a structure with active irreps led to a crash when ...
Pertinence: 5%
Pages
measure? qmin-qmax Do you want high (constant 1% dT/T) or low resolution (1-10% dT/T)? What is the active reflection area of your sample L=length along beam H=height The useful wavelength range is 2.5-25A
Pertinence: 4%
Pages
thickness 52 mm (2.05 inch) Electrical output Female high voltage BNC Active length 100mm (3.94 inch) Active width 42 mm (1.65 inch) Active thickness 40 mm (1.57 inch) Window material A5 Aluminium thickness ... lengths Scattering lengths and cross sections Estimating activation Using the following procedure and example, estimate the anticipated act ...
Pertinence: 30%
Pages
any time what sample is in the beam. After changing the sample you should check the radioactive activation of your sample with the 'babyline' of the instrument. Remember that Vanadium is activated but its ... Neutron scattering lengths General Neutron Scattering Information List of neutron scattering lengths Activation of elements Periodic Table of ...
Pertinence: 19%
Pages
in stroboscopic mode. Today, up to 256 complete diagrams or slices can be recorded, with a minimum active counting time window (open gate ) of 1 µs inside each slice of at least 30 µs (so a maximum slice
Pertinence: 16%
Pages
instrument D22 at the ILL, i.e. it should in particular have a spatial resolution of 7.5 x 7.5 mm, an active area of 96 x96 cm, a sensitivity of 75% for neutrons of 5Å wavelength, and a similar quiet count
Pertinence: 6%
Pages
D22 possesses the largest area multidetector ( 3 He) of all small-angle scattering instruments (active area 1 m 2 ), with a pixel size of 0.8 x 0.8 cm, i.e. 16 K resolution elements. The detector consists
Pertinence: 17%