of the beam paths contains a spin flipper which turns the incident spin up state into a spin down state. The exiting beams are a superposition of up and down state, each coming from a distinct beam path ... splits the neutrons coherently into two beam paths. The second blade acts as a mirror. The third blade superimposes the components from both ...
Recherche
Recherche de beams.
388 résultats ont été trouvés en 7 millisecondes.
Affiche les résultats de 141 à 150 sur 388.
Pages
Pertinence: 29%
Pages
[90.0,90.0,90.0]; u = [0,1,0]; % 1st reference axis: u=// to incident beam v = [0,0,1]; % 2nd reference axis: v=perp to incident beam omega=0;dpsi=0; % Unuseful (?) gl=2.37; % Estimated from the Braggs at
Pertinence: 4%
Pages
rangle (relative angle shift) values for each of the 9 D4c detectors. To set the zeroangle (i.e. direct beam angle) of the 9-detector ensemble: -z zeroangle To regroup a discontinous list of numor files (see
Pertinence: 5%
Pages
interface cell. The neutron beam then transmits through the solid and the oil film to reflect at the oil/water interface. Careful determination of the attenuation of the neutron beam through the oil is required ... reflected beam y56 = 2.726 ;Wanted Theta (deg) y58 = -1. ;-1 for reflection down, +1 for reflection up ;load OSS pattern into w2 ...
Pertinence: 17%
Pages
chapter "Neutron Optics" 1.1 Location of the diffractometer The PSD powder diffractometer D20 shares the beam tube H11 in the reactor (level C) with two other instruments: the PSD single crystal diffractometer ... described. A monochromator may be choosen by turning the changer in the protected monochromator and beam tube housing, muliple take-off ...
Pertinence: 22%
Pages
values by the instrumental factor (below) and the beam current as a fraction of l00mA to obtain the estimated values for the sample and actual beam conditions. Instrumental factors for LANSCE HIPD 1.00 ... radioactive before exposure to the neutron beam; apart from Tc and Pm, they are all a-particle emitters. Bismuth is a special case; it is ...
Pertinence: 19%
Pages
Instrument configuration par crpd 0(1): CRYOPAD mode off (on). CRYOPAD mode off switches on normal beam mode. Polarisation state spi (spo) sets polarization in (out) spi 1: flipper_in set "spin up" (negative ... (negative current) spi -1: flipper_in set "spin down" (positive current) spi 0: no current in flipper_in (beam roughly de-polarised) spi ...
Pertinence: 20%
Pages
serve a very limited number of applications. For reasons of intensity, a relatively large beam divergence, i.e. a beam cross-section larger than the sample size is accepted as well as wavelength resolutions ... pushing a button in the controlled area after checking the absence of any person before opening the beam. (04-Mar-2005) Instructions in ...
Pertinence: 15%
Pages
the size of the beam to lower the background. The sample, placed in an applied magnetic field, diffracts neutrons which are counted by the detector. The intensity of the diffracted beam depends on the initial ... Measuring with polarised neutrons in a high magnetic field configuration The unpolarised neutron beam coming from the hot source enters ...
Pertinence: 29%
Pages
(written in C) that enables to model very precisely a neutron instrument described as a series of beam-line components. A source component shoots off each neutron randomly (Monte-Carlo), and the particle ... some virtual detectors along the neutron path, to monitor the characteristics and flux of the neutron beam at that position. McStas provides a ...
Pertinence: 22%
