sample. Why aerodynamic (gas flow) levitation of the sample ? No container windows in the neutron beam and hence no additional background. Why laser heating ? No sample contamination by hot vapor from
Recherche
Recherche de beams.
388 résultats ont été trouvés en 3 millisecondes.
Affiche les résultats de 141 à 150 sur 388.
Pages
Pertinence: 19%
Pages
IN20 - Thermal neutron three-axis spectrometer with polarisation analysis IN20 is a thermal beam three-axis spectrometer for inelastic scattering experiments in various sample environments (eg. magnets
Pertinence: 21%
Pages
classical three axis spectrometry (TAS). The polychromatic beam from the thermal beam tube H13 arrives at the monochromator. The monochromatic diffracted beam is scattered by the sample, usually a single crystal ... material. The analyser measures the energy of the scattered beam. The scan shown here is an energy scan in which the energy of the ...
Pertinence: 30%
Pages
Imagine the focusing nose to be at the guide end). The neutron beam is pulsed by the "background" chopper. A rotating deflector sends the beam to the monochromator. A 90 degree Bragg relection from high quality ... band is selected by a velocity selector instead of a graphite deflector: The polychromatic neutron beam from the reactor is deflected ...
Pertinence: 28%
Pages
Simulated experiment A polychromatic (white), neutron beam is partially monochromatised by the two counter-rotating disc choppers, generating a packet of neutrons which then falls upon the monochromator ... angle selected to define the desired neutron wavelength by Bragg’s Law. The reflected monochromatic beam then passes to the Fermi chopper, ...
Pertinence: 26%
Pages
a rather broad Δλ/λ bandwidth (typically 15%) from the incident polychromatic neutron beam. The monochromatic beam is then polarised by a supermirror polariser which stops the neutrons with the "wrong"
Pertinence: 24%
Pages
Instrument 3D layout A cut of IN5B in a vertical plane along the beam axis (1) Main access gate (2) Choppers radiological protection (3) Monochromator choppers (4) Frame overlap and contaminant order choppers
Pertinence: 23%
Pages
dynamic modes in condensed matter by measuring the energy exchange between a monochromatic neutron beam and the sample. Applications Study of dynamics and relaxation properties in condensed matter exploiting
Pertinence: 22%
Pages
condensed matter by measuring the energy exchange between a monochromatic neutron beam and the sample. From the continuous, "white" beam delivered by the H15 neutron guide, a specific wavelength (and thus incident ... Fermi chopper pulses this monochromatic beam, setting the time t 0 of its interaction with the sample. A timer then measures the ...
Pertinence: 29%
Pages
Three intense neutron beams are extracted from a neutron guide by an assembly of three monochromators and are focused horizontally onto the sample. Each monochromator delivers a beam of distinct energy and ... and, thus, of distinct velocity due to different Bragg-scattering conditions. The neutron beams are pulsed by a Fermi chopper which allows ...
Pertinence: 26%