PG(002) 3He detector 50 mm Ø x 12 cm Instrument description IN3 is a classic three-axis spectrometer on a through-going neutron guide (Fig.1). A bi-faced monochromator with PG(002) and Cu(111) with variable
Recherche
Recherche de a.
1447 résultats ont été trouvés en 3 millisecondes.
Affiche les résultats de 141 à 150 sur 1447.
Pages
Pertinence: 12%
Pages
+33(0)4 76 20 7080 First Responsible PIOVANO Andrea Co-Responsible(s) BOEHM Martin Please, click on a person name to get his contact information.
Pertinence: 11%
Pages
space focussing of neutrons scattered by the sample in a very large solid angle, which are all then recorded with a relatively small single counter (a He3 gas detector). The focussing reflecting surface of ... optimised in a way such that all three corresponding contributions to the energy resolution are equal. It is important that the requested ...
Pertinence: 13%
Pages
but using a default binning corresponding to the wavelength specified: 0.7 A defaults of qbeg=0.0, qfin=17.0, qstep=0.001 (A^-1) 0.5 A defaults of qbeg=0.0, qfin=24.0, qstep=0.001 (A^-1) 0.35 A defaults ... In this computer you have a set of programs allowing you to produce a single diffractogramme from a series of numors, and to perform simple ...
Pertinence: 13%
Pages
the same protection same movements as a TAS The IMPS assembly comprises a multi-analyser made of 9 independent crystals, a computer controlled variable collimator and a position sensitive detector. It makes ... geometries, its use would be quite complicated without a computer assistance. Thus the software vIMPS was developed which offers both a ...
Pertinence: 13%
Pages
blades can seeEach plot correspond to an angle β of the analyser table. First measurements with a test sampleA phonon in germanium Applications IMPS is not yet commissioned. First tests in 2008 gave promising
Pertinence: 12%
Pages
cold source Monochromator graphite crystals intercalated with potassium 8.9 A monochromatic neutrons reflected towards guide H172A Ultra Cold Neutron (UCN) source Small size 4 He source 5 liters Environment ... project consists of designing and building a second-generation gravitational neutron spectrometer with ultra-high resolution. Its key ...
Pertinence: 13%
Pages
efforts of so many people, a unique GRANIT mirror has been completed and delivered to Grenoble on Friday 16 November. The GRANIT project consists of designing and building a second-generation gravitational ... ultra-high resolution. Its key property is the storage of UCN in a selected gravitationally bound state for extended period of time using a ...
Pertinence: 13%
Pages
analyzers provide a signal free of higher harmonic contamination when working with thermal neutrons (k f = 3Å -1 ). With cold neutrons the choice of k f = 1.4 Å -1 permits to access a window of energy transfers ... up to 1 meV while working with a Be-filter in the incident beam. The work at higher energy transfers with an unfiltered beam on IN14 ...
Pertinence: 12%
Pages
spectrometer D007 will deliver its first neutrons in 2025. The diffuse scattering spectrometer D7 is a general purpose neutron polarisation analysis spectrometer, designed to study nuclear and magnetic short
Pertinence: 10%
