(png - 1.47 Mi) The spectrometer equipped with the 15T magnet. Spectrometer
Recherche
Recherche de 1'".
1022 résultats ont été trouvés en 6 millisecondes.
Affiche les résultats de 141 à 150 sur 1022.
Pages
Pertinence: 15%
Pages
to flat positions) and the elliptically tapered guide end-section can be replaced by a straight m = 1 guide section to provide an incoming beam-divergence smaller 60’. To this end a three-stage lifting
Pertinence: 11%
Pages
ctor systems: conventional single analyzer/detector unit for classical three-axis experiments (Fig.1) multiplexed analyzer/detector system for mapping inelastic response over larger phase space areas (Fig
Pertinence: 13%
Pages
Fig. 1: Cyclic hexamer of adsorbed water in NaXWater molecules (in red) are located on W1 sites. The formation of a cyclic water hexamer in zeolite NaX Neutron powder diffraction is a valuable tool for ... cyclic hexamers of water molecules localised in the 12-ring windows between faujasite supercages (Fig. 1) which are stabilised by hydrogen bonds ...
Pertinence: 16%
Pages
magnetic moment appears alongside a change in crystal structure from monoclinic (M) to orthorhombic (O1) (fig. 1). Neutrons studies on D2B showed that, contrary to the expectations, applying a field as high as ... Fig. 1: The transition from monoclinic to orthorhombic structure in the alloy, Tb5Si2Ge2.Red balls: silicon or germanium atoms ; yellow ...
Pertinence: 16%
Pages
and that the wavelength variation of the polarisation down to 0.33Å was in good agreement with the 1/v dependency of the absorption cross-section. The team: E. Bourgeat-Lami, H. Humblot, W. Heil, F. Tasset
Pertinence: 12%
Pages
simultaneously the phase of the last magnetic atom was not taken into account correctly v1.5.2 | v1.5.1 & v1.5 (June 2018) v1.5.2 (June 2018) fixed a bug which showed the Multipoles tab in the Fit window without ... structure' v1.5.1 (June 2018) fixed a bug which led to a crash, when saving the *.dat file on Windows and Linux machines v1.5 (June ...
Pertinence: 20%
Pages
= 3.362 Å 1x10 7 n.cm -2 .s -1 polarising, less-flux, better resolution Co 0.92 Fe 0.08 (200) d = 1.771 Å 2x10 6 n.cm -2 .s -1 non-polarised, high flux, high resolution Cu (200) d = 1.807 Å 1x10 Zero-field ... hours Low-field option Electromagnet 0.01T < H < 0.6T 1.5K < T < 300K Vertical access -24° < ν < +5° High-field option 10T Cryomagnet 1.0T < ...
Pertinence: 17%
Pages
spectrometers. It also possesses a unique four circle dilution cryostat for temperatures down to 0.1K, and offers high reciprocal-space resolution and low intrinsic background, to medium real-space resolution
Pertinence: 12%
Pages
e mode, the offset C-shaped Eulerian cradle can be equipped with a helium-flow cryostat (1.6 K to 450 K, or 0.1 K to 10 K in dilution mode). This dilution cryostat is of an innovative design which allows
Pertinence: 15%