programme, a longer-term project (starting in 2023) would be to merge the SHARP spectrometers and the ILL RAMSES project at the end of a new dedicated guide. A bandwidth chopper positioned upstream of a horizontally ... chamber itself. It will be under vacuum. A removable foil between the sample and the inlet of the chamber will enable to operate ...
Recherche
Recherche de a.
1447 résultats ont été trouvés en 4 millisecondes.
Affiche les résultats de 131 à 140 sur 1447.
Pages
Pertinence: 13%
Pages
diffraction patterns. Instrument layout A large array of microstrip detectors provides not only a high counting rate but also a very good counting-rate stability. Combined with a very low+stable background counting ... - Disordered Materials Diffractometer D4, a two-axis diffractometer, uses short-wavelength neutrons from the hot source to measure ...
Pertinence: 13%
Pages
A general view of the instrument This top view of the instrument was taken in 2007 during measurements on aerodynamically-levitated samples melted via laser-heating.me.
Pertinence: 83%
Pages
position sensitive detector (PSD) mounted inside a vacuum time-of-flight chamber 4m from the sample. PSDs cover a large gapless detection surface (30m2) with a spatial resolution comparable to triple-axis ... . 620 K Instrument description IN5 is a general purpose direct geometry Time of Flight (ToF) spectrometer. It is used to study low-energy ...
Pertinence: 12%
Pages
overlap ratio. As an example, a wavelength of 5 Å and a chopper velocity of 8500rpm give a resolution of 100 µeV with a frame overlap ratio of 3 (as we are close from the boundary a ratio of 2 might be also ... 8500 rpm, i.e. half the maximal velocity, for a frame overlap ratio of 1 (same velocity for all the choppers). Doubling this velocity leads ...
Pertinence: 23%
Pages
A view of the fan-like neutron-detector The detector assembly is a array of nine 1D position sensitive detectors with an angular resolution of 0.125º. The available 2θ-range is 1.5º to 140º. Because there ... there are 7º in between two detectors, 2-positions scans are required to produce a complete diffraction pattern up to 135º. For a complete ...
Pertinence: 83%
Pages
crystal pieces, concentrates the divergent incident beam onto a small area at the sample position. The full use of the available solid angle gives a high incident flux. The variable curvature of the monochromator ... faces and the Fermi chopper. The background choppers are rapidly pulsating beam shutters which act as a low-pass filter. Thus they ...
Pertinence: 12%
Pages
ROLS Stephane Co-Responsible(s) FAK Bjorn ZBIRI Mohamed Technician(s) MEULIEN Olivier Please, click on a person name to get his contact information.
Pertinence: 11%
Pages
46 cm, 55 cm height) with a wide-angle thin aluminum exit window. The samples are usually contained in cylindrical vanadium cans. Vertical and horizontal slits allow defining a maximum illuminated cross-section ... cells covers therefore 8º in 2θ. Since there is a 7º gap between two detectors, at least 2 angular positions of the 9-detector ensemble ...
Pertinence: 13%
Pages
its aperture. This quasi-monochromatic beam is scattered by the sample: usually a gas, a liquid, an amorphous or a powdered material. The intensity of the scattered neutrons is measured by an array of nine ... hot neutron beam tube H8 is diffracted by the monochromator, where a single wavelength is selected. The diffracted beam passes through a ...
Pertinence: 13%
