rangle (relative angle shift) values for each of the 9 D4c detectors. To set the zeroangle (i.e. direct beam angle) of the 9-detector ensemble: -z zeroangle To regroup a discontinous list of numor files (see
Recherche
Recherche de beams.
400 résultats ont été trouvés en 4 millisecondes.
Affiche les résultats de 71 à 80 sur 400.
Pages
Pertinence: 5%
Pages
amagnetic no mechanism on the beam developed by TEKNIKER Variable collimator system blades Borated Al 1mm thickness size 120 mm height 200 mm long Definition of the outgoing beam Prevents cross-talk between ... modes. Its main characteristics are: possibility on working focused or imaging no mechanism on the beam mechanics completely amagnetic IMPS ...
Pertinence: 26%
Pages
transfers of up to 1 meV while working with a Be-filter in the incident beam. The work at higher energy transfers with an unfiltered beam on IN14 needs some experience and caution. A valuable tool when using
Pertinence: 24%
Pages
Neutron beam The neutron beam from the H22 guide is collimated to a halo-free pencil beam of 1.5cm diameter. The neutron beam intensity at the target position is of 10 8 n.cm -2 .s -1 . The collimation ... gamma ray background all apertures are doubled with 5 cm thick lead absorbers downstream the neutron beam direction. The sequence of apertures ...
Pertinence: 30%
Pages
Instrument Data beam size at sample 40 x 10 mm 2 incident wavelength range 2 - 30 Å scattering plane vertical Figaro Time-of-flight 4 choppers Frame overlap mirrors [20Å] [30Å] white beam flux at sample ... sample ~10 8 n cm -2 s -1 angle undeflected beam 0.62˚ angles deflected beam -2.5˚ < θ < 3.8˚ (horizontal) constant wavelength resolution δλ/λ ...
Pertinence: 28%
Pages
% 0.4, 4 4.8 92.3 1.8 × 10 6 3.55 4.4 % 0.3, 2.5 5.7 116.3 0.8 × 10 6 2.51 3.7 % 0.2, 2.1 Maximum beam size at sample: 55 × 25 mm Technical Specifications Monochromator 3 × HOPG (002), each with vertical ... the cold neutron guide H15, monochromates the neutrons with wavelengths of 3.1 Å, 4.8, or 5.7 Å. The beam is polarized using a focusing, m = ...
Pertinence: 23%
Pages
interface cell. The neutron beam then transmits through the solid and the oil film to reflect at the oil/water interface. Careful determination of the attenuation of the neutron beam through the oil is required ... reflected beam y56 = 2.726 ;Wanted Theta (deg) y58 = -1. ;-1 for reflection down, +1 for reflection up ;load OSS pattern into w2 ...
Pertinence: 18%
Pages
to 26 % (depending on chopper pair & detector distance) Collimation 4 movable guide sections 2.5 m Beam nose 2.8 m Guide cross-section 30 x 30 mm Source-to-sample distances (m) 2.8, 5.3, 7.8, 10.3, 12.8 ... mode: a velocity selector and flexible system of inter-collimation apertures defines the neutron beam. TOF mode: a chopper system allows an ...
Pertinence: 25%
Pages
Guide hall, thermal beam H25 Monochromators In primary shielding: PG (002) vertical focussing in reflection Cu (200) flat in transmission In secondary shielding (for polarized neutrons): Heusler (111) ... to the right or to the left, with a maximum Bragg angle 2θB ≈ 130° on both sides; using a normal beam mode: the lifting detector is mounted in ...
Pertinence: 20%
Pages
cold source; the short rotor and high transmission of its velocity selector; the relatively large beam cross-section (55 x 40 mm). Wavelength selection A relatively narrow wavelength band (normally 10 ... of eight sections. Each section comprises three tubes, any one of which can be positioned on the beam axis. One tube contains a neutron guide of ...
Pertinence: 22%