Instrument configuration par crpd 0(1): CRYOPAD mode off (on). CRYOPAD mode off switches on normal beam mode. Polarisation state spi (spo) sets polarization in (out) spi 1: flipper_in set "spin up" (negative ... (negative current) spi -1: flipper_in set "spin down" (positive current) spi 0: no current in flipper_in (beam roughly de-polarised) spi ...
Recherche
Recherche de beams.
400 résultats ont été trouvés en 4 millisecondes.
Affiche les résultats de 61 à 70 sur 400.
Pages
Pertinence: 21%
Pages
condensed matter by measuring the energy exchange between a monochromatic neutron beam and the sample. From the continuous, "white" beam delivered by the H15 neutron guide, a specific wavelength (and thus incident ... Fermi chopper pulses this monochromatic beam, setting the time t 0 of its interaction with the sample. A timer then measures the ...
Pertinence: 29%
Pages
sensitive difference measurements as in the case of small scattering-length contrast. D4 shares the beam tube H8 with the IN1 triple-axis and Lagrange (Be-filter) spectrometers, and is therefore available
Pertinence: 21%
Pages
1×2×λ o [°] vertical divergence (no collim.) ~ 0.1×3×λ o [°] Collimation before sample - / 30' / 60' beam size at the sample ~ 15×50 mm 2 flux at the sample at 5.0 Å 6.83×10 5 [n/cm 2 /s] Detectors detector
Pertinence: 14%
Pages
[90.0,90.0,90.0]; u = [0,1,0]; % 1st reference axis: u=// to incident beam v = [0,0,1]; % 2nd reference axis: v=perp to incident beam omega=0;dpsi=0; % Unuseful (?) gl=2.37; % Estimated from the Braggs at
Pertinence: 5%
Pages
components of the beam conditioning part are the two background choppers, the double curvature mono-chromator with four faces and the Fermi chopper. The background choppers are rapidly pulsating beam shutters which ... Reactor hall, thermal beam H12 Monochromators PG 002: 2.20 ... 3.60 Å PG 004: 1.10 ... 1.80 Å Cu 220: 0.85 ... 1.50 Å Cu 111: 1.25 ...
Pertinence: 28%
Pages
respectively. A high-transmission monitor located between monochromator and beam-defining slits is used for normalisation to incident beam intensity. The sample is mounted in an evacuated cylindrical bell jar ... Reactor Hall, Level C, Hot Beam H8 Monochromators Si(11L=1,2,3), Cu(220) and Cu(331), all 20 cm high and 23 cm wide, all with variable ...
Pertinence: 23%
Pages
experiment The polychromatic neutron beam from the hot neutron beam tube H8 is diffracted by the monochromator, where a single wavelength is selected. The diffracted beam passes through a filter to remove ... remove the harmonics and then through slits to limit its aperture. This quasi-monochromatic beam is scattered by the sample: usually a gas, a ...
Pertinence: 30%
Pages
Guide hall n° 1, thermal guide H24 beam cross section 30 x 75 mm 2 Monochromator crystal d -spacing in Å k i in Å -1 flux in 10 6 n cm -2 s -1 PG (002) 3.355 1.3 - 3.3 2.662 9.3 Cu (111) 2.087 2.0 - 5
Pertinence: 22%
Pages
Reactor hall, hot beam H 8 beam size: 20 cm height x 5 cm width Monochromators size: 20 cm height x 18 cm width variable vertical focussing crystal spacing d/Å Ei range (meV) ΔEi (meV) Cu(220) 1.278 [26-500] ... Er, Sm, Hf ...) can be used to suppress higher order contaminations from the incident beam or in the scattered beam. An oriented Pyrolytic ...