nuclear physics and applied nuclear physics aspects. Three other ones (PF1 - intense cold neutron beam facility, PF2 and SuperSUN - ultracold neutron facility) are covering mainly neutron particle physics ... thermal neutron induced reactions. It is composed of a highly collimated halo-free pencil neutron beam impinging on a stable or radioactive ...
Recherche
Recherche de beams.
399 résultats ont été trouvés en 2 millisecondes.
Affiche les résultats de 61 à 70 sur 399.
Pages
Pertinence: 27%
Pages
use with polarised beam (spare) 18PG1000BN5 VX-5 Type 200 @ 300 K or 100 @ 300 K cBN or Al2O3-ZrO2 anvils TiZr gaskets - Ø2.4 x 1.3 or Ø4.8 x 2.7 247ILCCHP180 for non-polarised beam 19PG1000BN5 VX-5 Type ... l.fr is required for their reservation and preparation. Code Pressure max. (kbar) Material in the beam Thickness (mm) Sample Volume Ø x height ...
Pertinence: 27%
Pages
Guide hall n°2, cold guide H522 Incident wavelength 3 ... 12Å Beam profile Incident beam divergence 20 mrad Beam cross section 55 x 120 mm 2 Velocity selector Incident wavelength 3 ... 12Å Velocity selector ... this is achieved by constructing large coils which are placed with their central axis parallel to the beam axis. This has strongly limited ...
Pertinence: 27%
Pages
(ESRF) are respectively the leading European centres for research using neutron and synchrotron X-ray beams. They share a joint site and provide advanced research facilities for users from European universities ... neutron measurements, enhancing also faster alignment of complex/large components directly at the beam line. Other lab equipment from ...
Pertinence: 27%
Pages
horizontal cold source of ILL high-flux reactor. It comprises the primary spectrometer, with the incident beam casemates and the monochromator shielding, and the secondary spectrometer, with the sample table and ... wavelength of λ/2, λ/3 etc. will be placed at the exit of the neutron guide in the casemate. The incident beam casemate as well as the ...
Pertinence: 27%
Pages
49, 176ILHV49, 203OXHV39 The distance between the mixing chamber and the beam axis is 90 mm. The space available below the beam axis is 48 mm. Type Dilution insert Tmin 40mK Tmax 300K Instrument Pool Sensor
Pertinence: 27%
Pages
49, 176ILHV49, 203OXHV39 The distance between the mixing chamber and the beam axis is 90 mm. The space available below the beam axis is 48 mm. Type Dilution insert Tmin 40mK Tmax 300K Instrument Pool Sensor
Pertinence: 27%
Pages
Simulated experiment A polychromatic (white), neutron beam is partially monochromatised by the two counter-rotating disc choppers, generating a packet of neutrons which then falls upon the monochromator ... angle selected to define the desired neutron wavelength by Bragg’s Law. The reflected monochromatic beam then passes to the Fermi chopper, ...
Pertinence: 27%
Pages
the principal challenges during strain experiments is the movement of the specimen about the neutron beam (gauge volume). SALSA uses a unique hexapod design which has significant advantages over traditional ... during an experiment. A 300mm diameter, 500mm long steel pipe section is maneuvered around the neutron beam for measurements of lattice ...
Pertinence: 27%
Pages
primary white beam is reflected by a focussing monochromator made of 9 highly oriented pyrolytic graphite (HOPG) providing an important flux at the sample. The monochromator housing has two beam holes at take-off ... 85° and 115°, corresponding to 4.5 Å and 5.6 Å beams with HOPG and incorporates the slit systems and cooled Beryllium filter in a way ...
Pertinence: 27%