Guide hall nº1, cold neutron guide H112 beam size at sample 30 x 30 mm 2 (smaller for BATS t.b.d.) Sample environment cryofurnace (50 mm); max. sample diameter 48 mm 1.8 K - 560 K cryostat (70 mm); max
Recherche
Recherche de beams.
401 résultats ont été trouvés en 3 millisecondes.
Affiche les résultats de 51 à 60 sur 401.
Pages
Pertinence: 14%
Pages
Beam Polarisation 0.843 Å - Erbium filter Beam Polarisation with Heusler at 0.843Å/114meV Erbium filter - code: Er (ID #1) - 0.5mm thick - efficiency: 96% - transmission: 80% ... with the 10 Tesla cryomagnet ... chamber (18x30 mm 2 beam) (+) Polar. / H4A (-) Polar. / H4A (+) Polar. / H4B (-) Polar. / H4B +0.906 ± 0.003 -0.906 ± 0.003 +0.962 ± 0.003 ...
Pertinence: 100%
Pages
polarising guide H511 Neutron beam characteristics diameter at sample position 40 mm incident wavelength 6 ... 25 Å monochromatisation Δλ/λ (FWHM) 15% (velocity selector) incident beam divergence <17 mrad polariser
Pertinence: 24%
Pages
insert of the cryomagnet into the beam. It is rotated so that a given set of crystal planes diffracts the beam. The detector is rotated and lifted towards the diffracted beam. The magnetisation distribution ... enter beam tube H4 and go to the polarising monochromator which diffracts only neutrons with a given wavelength and spin polarisation. The ...
Pertinence: 30%
Pages
the size of the beam to lower the background. The sample, placed in an applied magnetic field, diffracts neutrons which are counted by the detector. The intensity of the diffracted beam depends on the initial ... Measuring with polarised neutrons in a high magnetic field configuration The unpolarised neutron beam coming from the hot source enters ...
Pertinence: 30%
Pages
slightly increases the energy resolution width. A vertically curved Graphite deflector focusses the beam onto the sample. The scattered neutrons are energy analysed by a set of seven spherically curved composite ... large solid angle of 0.18 sr. An additional three circular analysers centred around the transmitted beam cover the small-angle region. ...
Pertinence: 22%
Pages
neutron polarization vector at will, before and after the sample. In the first video the scattered beam polarization vector is antiparrallel to the input polarization which means that the polarization rotates ... which is true for collinear antiferromagnetic samples. Other kinds of magnetic samples modifies the beam polarization in a much complex ...
Pertinence: 25%
Pages
polarized neutrons a supermirror bender can be mounted after the first collimator to polarize the incident beam. A curved Heusler (111) analyser replaces the normal analyser. A small field (< 15 Oe; magnitude and
Pertinence: 16%
Pages
bottle filled up with that polarised gas would be an effective neutron polariser even for large white beams. This technique was made trully operational for the 1st time in November 1996 by the historical experiment ... He spin-filter on D3. F. Tasset is looking at the ratemeter to get a first estimate of the neutron-beam polarisation. (movie ...
Pertinence: 25%
Pages
Reactor hall, thermal beam H10 Diameter of the “in-pile” beam tube extremity Ø = 170 mm Virtual source Adjustable width: typically used 30 mm wide for PG and Cu monochromators, 25 mm wide for Si monochromators ... available openings are 20’, 30’ and 40’ with additional 60’ for the secondary spectrometer. The primary beam shielding drum allows ...
Pertinence: 23%